background image

                                                                                                                                 

IP Paging Microphone User Manual 

       

                                                                                17 

Fault Exclude 

Terminal can not login the server? 

1

Check the server software and main control computer is normally open or not. It must close all the firewall before open 

the service software, (including the systemic firewall and other antivirus software.) 

2

Check  the  network  connection  is  normally  working  or  not.  When  the  terminal  is  power  on,  the  network  port  green 

indicator light will be normal on, and orange indicator light will rapidly short flicker, it means the cable hard-link is normal. If the 

network port green indicator light is not light up, there is network hard-link problem, please check the cable and switch which is 

connected the terminal, check if there is any damage and poor contact abnormal working. 

3

Check the terminal IP setting. Checking the terminal ID NO, server IP, local IP and gateway IP these parameters is correct 

or not. 

 

Terminal can not login to the server, intercom and broadcast is not normal? 

1

Check the bandwidth is limited or not( use the network bandwidth tools to test it), it should broaden the            bandwidth if 

it`s limited. 

2

Detected a lot of data flow of bandwidth, please restrict this IP address. 

3

Checking  the  ID  number  and  host  IP  address  is  conflict  or  not,  please  reset  the  ID  number  or  host  IP  address  if  it`s 

conflict. 

4

If ID number and IP address is not conflict, but it can not make normal conversation, please acquire the data package 

and submit to the factory for analyzing. 

 

How  to  solve  the  warning  of  “terminal  network  service  (UDP)”  failed  during  the  process  of  the  starting  the  service 

software? 

Server local network connection is disconnected, connect the local network cable, exit the service software and 

Restart, it will be ok. 

 

Can not be transferred? 

1

  Target terminal is not login the server. 

2

  Target terminal is not support for transfer function. 

 

Web display abnormal? 

Emptying the cache or change the browser. 

 

How to modify the account number and password to login the web page? 

1

Click the password setting of the web page. 

2

Please input previous user name and password under the original user name and password respectively. 

3

Input the new user name and password in the new one. 

4

Input the new password in the command confirmation. 

5

Click for save. 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for NAS-8530

Page 1: ......

Page 2: ...ameters 8 Login WEB interface 8 Network Parameters 8 Server Parameters 9 Shortcut Function 10 Offline Intercom 11 WEB management 12 Reboot 13 Reset to Defaults 13 Update Firmware Note otherwise specia...

Page 3: ...y if you continue to use it will likely fires or shock The smoke or odor of the machine The inside of the machine is flooded by water or foreign bodies intrusion Machine falling or machine shell damag...

Page 4: ...conds Built in 3W power loudspeaker large voice small distortion With detachable hose type microphone pole longer life good maintenance Support for incoming calls outgoing calls which is showed in Chi...

Page 5: ...s this key to enter into the broadcasting status Volume Key When it s playing the audio by pressing this key to increase the speaker volume Volume Key When it s playing the audio by pressing this key...

Page 6: ...t with the server related cables in order to make the terminal login normally Alarm input or output interface With alarm input and output port for linkage with external device factory defaults as alar...

Page 7: ...2A 1pcs 4 Certification 1pcs 5 Installation instructions 1pcs Installation 1 Microphone pole groove install accordance with the pedestal raised groove as follows 2 Screwing the rotary knob tightly ac...

Page 8: ...ther port connect with the switcher Interface Description After the power on for 15 seconds to enter the main interface successful it will display the time and date information Main interface IP pagin...

Page 9: ...rs according to the using environment there are two methods Keyboard Operation 1 Press or info key input the terminal password 123456 enter the system setting interface Press key to move press numeric...

Page 10: ...setting User Define Terminal Parameters Login WEB interface 1 Please input the IP Paging Microphone IP address to the browser address column the factory default IP address is 192 168 1 101 then enter...

Page 11: ...the right to control devices VOD and broadcast etc Alternate server IP Se the IP address of Preferred server the factory defaults is 192 168 1 14 Login server mode The device can log onto the server...

Page 12: ...er playing Ringing volume Terminal volume adjustment range 0 15 Ringing output mode Set ringing output mode of the terminal horn or line output can be choose Query original ID Set the terminal query o...

Page 13: ...tton Select the function to intercom on the web page of IP paging microphone and configure terminal number of offline intercom to the shortcut call button Offline call number is decided by the number...

Page 14: ...IP paging microphone and then click Save Completed settings After close the server software it could call offline terminal normally without the affect of restart WEB management You can modify the web...

Page 15: ...e the factory offered firmware update file click firmware upgrade key to upgrade Note if you need to upgrade the firmware please contact the dealer Other functions In addition to above function IP pag...

Page 16: ...rd Rdc070 in appeared login window chick Log on enter into FTP it can use the server build in WAN program making tools to switch the audio documents Remote playing file AudioFile Make the converted au...

Page 17: ...p the intercom mapping between the keyboard and the corresponding terminal for the details please refer to the shortcut function settings on the web page Press F1 F8 key on the main interface or the 1...

Page 18: ...h the target terminal Note after pressing the number key use interval to come out and then press broadcast key to realize multiple terminal broadcasts For example to select terminal 1 terminal 2 termi...

Page 19: ...andwidth tools to test it it should broaden the bandwidth if it s limited 2 Detected a lot of data flow of bandwidth please restrict this IP address 3 Checking the ID number and host IP address is con...

Page 20: ...part of the manual is allowed to be reproduced or used for commercial purpose And SPON shall take no responsibility for any losses or damages caused by the illegal reproduction and conversion of the m...

Reviews: