Echo cancellation    It`s enable by default, it will have echo when it`s disable   

The third parties 

talking function 

Set the third party talking function, the defaults is enable. 

Broadcast input 

volume 

Terminal volume adjustment, range 0~15 

Broadcast output 

volume 

Terminal volume adjustment, range 0~15 

Broadcast 

sampling rate 

Set broadcast sampling rate,8K or 22K for optional, the defaults is 22K. 

Broadcast 

ADPCM coding 

Set whether intercom ADPCM encoding is enabled 

Broadcast prompt 

tone 

Set the broadcast prompt tone, the defaults is enable. 

File broadcasting 

Auto-pause: in the process of initiating audio file broadcasting to other terminals, a 

music will stop automatically after playing. 

Loop play: in the process of initiating audio file broadcast to other terminals, a music 

will be played repeatedly after playing. 

Ringing volume 

Terminal volume adjustment, range 0~15 

Ringing output 

mode 

Set ringing output mode of the terminal,horn or line output can be choose 

Query original ID 

Set the terminal query original ID number 

Number of queries 

Set the number of terminal queries 

Terminal language   

Set the language of the terminal WEB page, Chinese or English can be choose,   

it’s 

default as Chinese. 

Intercom 

password settings 

Set the password to enter the Settings menu 

Shortcut Function 

Customize the terminal ID number or partition number corresponding to the key on the main interface and extension board in 

the shortcut function list. ( Please enter” ID#terminal number”, when setting shortcut calling to terminal ). Select the function to 

intercom, broadcast or partition broadcast (default is intercom), then click” Save” after setting. 

After the shortcut mode parameters is workable, press 

F1

-

F8

  key on the main interface or the 16 the shortcut key on 

the expansion panel can make the intercom calling or broadcasting to the corresponding target terminals. 

 

Summary of Contents for NAS-8530

Page 1: ......

Page 2: ...ameters 8 Login WEB interface 8 Network Parameters 8 Server Parameters 9 Shortcut Function 10 Offline Intercom 11 WEB management 12 Reboot 13 Reset to Defaults 13 Update Firmware Note otherwise specia...

Page 3: ...y if you continue to use it will likely fires or shock The smoke or odor of the machine The inside of the machine is flooded by water or foreign bodies intrusion Machine falling or machine shell damag...

Page 4: ...conds Built in 3W power loudspeaker large voice small distortion With detachable hose type microphone pole longer life good maintenance Support for incoming calls outgoing calls which is showed in Chi...

Page 5: ...s this key to enter into the broadcasting status Volume Key When it s playing the audio by pressing this key to increase the speaker volume Volume Key When it s playing the audio by pressing this key...

Page 6: ...t with the server related cables in order to make the terminal login normally Alarm input or output interface With alarm input and output port for linkage with external device factory defaults as alar...

Page 7: ...2A 1pcs 4 Certification 1pcs 5 Installation instructions 1pcs Installation 1 Microphone pole groove install accordance with the pedestal raised groove as follows 2 Screwing the rotary knob tightly ac...

Page 8: ...ther port connect with the switcher Interface Description After the power on for 15 seconds to enter the main interface successful it will display the time and date information Main interface IP pagin...

Page 9: ...rs according to the using environment there are two methods Keyboard Operation 1 Press or info key input the terminal password 123456 enter the system setting interface Press key to move press numeric...

Page 10: ...setting User Define Terminal Parameters Login WEB interface 1 Please input the IP Paging Microphone IP address to the browser address column the factory default IP address is 192 168 1 101 then enter...

Page 11: ...the right to control devices VOD and broadcast etc Alternate server IP Se the IP address of Preferred server the factory defaults is 192 168 1 14 Login server mode The device can log onto the server...

Page 12: ...er playing Ringing volume Terminal volume adjustment range 0 15 Ringing output mode Set ringing output mode of the terminal horn or line output can be choose Query original ID Set the terminal query o...

Page 13: ...tton Select the function to intercom on the web page of IP paging microphone and configure terminal number of offline intercom to the shortcut call button Offline call number is decided by the number...

Page 14: ...IP paging microphone and then click Save Completed settings After close the server software it could call offline terminal normally without the affect of restart WEB management You can modify the web...

Page 15: ...e the factory offered firmware update file click firmware upgrade key to upgrade Note if you need to upgrade the firmware please contact the dealer Other functions In addition to above function IP pag...

Page 16: ...rd Rdc070 in appeared login window chick Log on enter into FTP it can use the server build in WAN program making tools to switch the audio documents Remote playing file AudioFile Make the converted au...

Page 17: ...p the intercom mapping between the keyboard and the corresponding terminal for the details please refer to the shortcut function settings on the web page Press F1 F8 key on the main interface or the 1...

Page 18: ...h the target terminal Note after pressing the number key use interval to come out and then press broadcast key to realize multiple terminal broadcasts For example to select terminal 1 terminal 2 termi...

Page 19: ...andwidth tools to test it it should broaden the bandwidth if it s limited 2 Detected a lot of data flow of bandwidth please restrict this IP address 3 Checking the ID number and host IP address is con...

Page 20: ...part of the manual is allowed to be reproduced or used for commercial purpose And SPON shall take no responsibility for any losses or damages caused by the illegal reproduction and conversion of the m...

Reviews: