Data di emissione:
Dicembre, 2018
Revisione:
1
Pag. :
43/80
- Unscrew the securing bolt (S) in the direction
of the arrow (threading on the left), pull off of
the mixing unit (U), and remove the sealing
washers (X) and (T) (see figure 18).
Caution
Avoid the use of abrasive cleaners which
can damage the finish. Do not put the parts
in a dishwasher. Dishwasher may damage
some parts such as the clear plastic bowls
and auger gears.
- Thoroughly wash all the removed components
with hot water and mild dishwashing detergent,
but do not use abrasive detergents or powders
that can damage the bowl.
- Bring KAY-5
®
Sanitizer/Cleaner with a 100ppm
dilution (1 Oz packet of KAY-5
®
+2 ½ gallons of
water) (the sanitizing product shall comply with
40 CFR §180.940).
!IMPORTANT!
The type and concentration of sanitizing
agent shall comply with 40 CFR §180.940
- Rinse well and then place all the components
in the sanitizer solution; for proper sanitizing
the parts must remain fully plunged as
recommended by the sanitizer manufacturer
(KAY-5 sanitizer suggest at least 1-2 minutes).
IMPORTANT
Carefully follow the instructions of the
sanitizer manufacturer with regard to
timing and method of use.
- Once the correct times for sanitising have
been respected, remove and dry all components
on a clean surface. DO NOT RINSE.
- Thoroughly wash the evaporator and the drip
tray surfaces with a sponge soaked with the
sanitizer (see fig.19), leave at least 1-2 minutes
and let it dry, do not rinse.
Fig. 18
Fig. 19
Summary of Contents for IPro 1 Slusher ECO
Page 75: ...Data di emissione Dicembre 2018 Revisione 1 Pag 75 80 16 SCHEMA ELETTRICO WIRING DIAGRAM ...
Page 76: ...Data di emissione Dicembre 2018 Revisione 1 Pag 76 80 ...
Page 77: ...Data di emissione Dicembre 2018 Revisione 1 Pag 77 80 ...
Page 78: ...Data di emissione Dicembre 2018 Revisione 1 Pag 78 80 ...