20
Fig. 8
7 - CONNECTION TO POWER SUPPLY MAINS
For your personal safety, before inserting the plug
into the electrical outlet, as previously explained in
paragraph 7, carefully read the following
precautions:
- The electrical safety of the FROSTY DREAM slush
machine can only be achieved if the machine is
properly connected to an efficient grounding
system, in compliance with current national safety
standards. Therefore, the manufacturer cannot be
held responsible for damage and/or injury caused
by failure to properly ground the machine.
- For a safe and correct installation, it is necessary to
provide for a special outlet, with contacts having an
open distance equal to or greater than 3 mm,
controlled by an omnipolar circuit breaker,
conforming to current national security standards
(see fig. 8).
- The power supply cable must not, in any way, for its
entire length, be compressed, extension cords may
not be used, and finally, the plug must be removed
from the outlet with a slight pulling movement, after
having first cut-off the power supply.
- Do not obstruct the ventilating grill and heat
dispersion grill, since an insufficient ventilation
may not only reduce the efficiency of the machine,
causing it to function inadequately, but may also
cause serious damage to the machine.
IMPORTANT:
IF THE POWER SUPPLY CABLE IS DAMAGED,
IT MUST BE REPLACED BY QUALIFIED PERSONNEL
ONLY IN ORDER TO PREVENT ALL POSSIBLE RISKS.
Summary of Contents for FROSTY DREAM 2
Page 2: ......
Page 63: ...63 ESPLOSO FROSTY DREAM 2 EXPLODED VIEW FROSTY DREAM 2 ...
Page 64: ...64 SCHEMA ELETTRICO FROSTY DREAM 2 WIRING DIAGRAM FROSTY DREAM 2 ...
Page 65: ...65 ESPLOSO FROSTY DREAM 3 EXPLODED VIEW FROSTY DREAM 3 ...
Page 66: ...66 SCHEMA ELETTRICO FROSTY DREAM 3 WIRING DIAGRAM FROSTY DREAM 3 ...
Page 69: ...69 NOTES ...
Page 70: ...70 NOTES ...