40-SOTWD Set-Up Instructions 

Step 1: 

Finding a location for the proportioner 

 

Locate an area for tank installation, if possible near the air pump for the overhead reels and 
water line. 

 

Unit must be hung on a concrete wall.  

 

 

Step 2: 

Installing the unit on the wall 

 

At the final location of the unit measure and mark a level line 50” from the floor.  

 

Detach metal wall bracket from the back of the unit. 

 

Place the bottom of the metal bracket level with the line and mark the four mounting holes. 

 

Re-attach metal bracket to the proportioner using all six bolts, making sure they are all snug. 

 

Using a hammer drill, drill the four pre-marked holes with a 5/8” bit. 

 

Install the four 3/8” lead anchors into the holes.  

 

Hang unit on the wall using the four predrilled anchors. Secure with the supplied washers and 
screws. 

 

 

Summary of Contents for On Tap

Page 1: ...BACK FLOW PREVENTER 1 1 40 SOTWD Proportioner 2 1 Windshield washer fluid hydrometer 3 1 Magnetic snap action float 4 1 Poly Float with chain 5 4 Magnetic snap action float mounting screws 6 1 Methano...

Page 2: ...omer is responsible for ensuring that he or she properly dilutes the methanol concentrate to be in compliance with all federal state local laws and regulations Although the manufacturer has attempted...

Page 3: ...location of the unit measure and mark a level line 50 from the floor Detach metal wall bracket from the back of the unit Place the bottom of the metal bracket level with the line and mark the four mou...

Page 4: ...l drum of methanol is grounded Wire and alligator clip is recommended Drill a 7 16 hole in the center of the concentrate spout cap Locate the concentrate hose inside the proportioner and through the t...

Page 5: ...aded hole on the proportioner Step 5 Product Installation Locate the nearest water line Connect to the back of the magnetic float valve located on the top of the machine Use a line for this procedure...

Page 6: ...setting valve 2 turns to the left and open the black on off valve Procedure 3 For a 20F product turn setting valve 4 turns to the left and open black on off valve Leave 1 on off valve open For a 32 F...

Page 7: ...essure air 5 PSI Recommended through the hose to remove any build up If blowing the hose out does not solve the problem fully submerge the end of the hose and allow to soak for one hour in water or me...