background image

P a g e

 | 

 

www.SPLASHwash.com

 

Questions? 

(888) 784-0802

 

 

COMPLIANCE WITH LAW 

The Equipment is designed to dispense windshield washer fluid containing methanol, which is a 
volatile organic compound (VOC).  The United States Environmental Protection Agency (EPA) regulates 
the use of VOCs and specifically limits the amount of methanol that can be used in products.   
 
The Equipment must be used in compliance with federal, state, and local laws and regulations.  The 
EPA has regulated that under no circumstances shall there be more than 35% methanol by weight in 
the final product.  Please see the following website for more details: 

http://www.gpo.gov/fdsys/pkg/FR-1998-09-11/pdf/98-22660.pdf

. The concentrate provided by the 

manufacturer and distributor must be diluted to comply with federal, state, and local VOC regulations.  
For example, California, Arizona, Georgia, Texas and Oregon all have state and/or local laws that 
further regulate the amount of methanol that can be in products.  Other states may have such laws as 
well.  The customer is responsible for ensuring that he or she properly dilutes the methanol 
concentrate to be in compliance with all federal, state, local laws and regulations.  
 
Although the manufacturer has attempted to ensure that its equipment complies with all federal, state 
and local laws and regulations, neither the manufacturer nor the distributor can be responsible for nor 
guarantee that the customer will use the equipment in accordance with all laws and regulations.  
Therefore, customer agrees that neither the manufacturer nor the distributor shall be held responsible 
or liable for the use of this equipment in violation of federal, state and local laws and regulations.  In 
addition, customer acknowledges and agrees equipment must be properly installed according to federal, 
state and local laws and regulations, to include a back-flow preventer on the water line.  It is customer’s 
the responsibility to comply with federal, state and local laws and regulations pertaining to proper use 
and installation of the equipment. 

 

 

 

 

 

 

NOTICE: THE METHANOL BARREL MUST BE GROUNDED 

NOTICE: A back-flow preventer in compliance with local 
and/or state requirements must be installed on the water 
line to bring the unit to safety standards. 

 

 

 

Summary of Contents for On Tap

Page 1: ...BACK FLOW PREVENTER 1 1 40 SOTWD Proportioner 2 1 Windshield washer fluid hydrometer 3 1 Magnetic snap action float 4 1 Poly Float with chain 5 4 Magnetic snap action float mounting screws 6 1 Methano...

Page 2: ...omer is responsible for ensuring that he or she properly dilutes the methanol concentrate to be in compliance with all federal state local laws and regulations Although the manufacturer has attempted...

Page 3: ...location of the unit measure and mark a level line 50 from the floor Detach metal wall bracket from the back of the unit Place the bottom of the metal bracket level with the line and mark the four mou...

Page 4: ...l drum of methanol is grounded Wire and alligator clip is recommended Drill a 7 16 hole in the center of the concentrate spout cap Locate the concentrate hose inside the proportioner and through the t...

Page 5: ...aded hole on the proportioner Step 5 Product Installation Locate the nearest water line Connect to the back of the magnetic float valve located on the top of the machine Use a line for this procedure...

Page 6: ...setting valve 2 turns to the left and open the black on off valve Procedure 3 For a 20F product turn setting valve 4 turns to the left and open black on off valve Leave 1 on off valve open For a 32 F...

Page 7: ...essure air 5 PSI Recommended through the hose to remove any build up If blowing the hose out does not solve the problem fully submerge the end of the hose and allow to soak for one hour in water or me...

Reviews: