GENERAL REQUIREMENTS
•
The installation must also be in accordance with the relevant parts of local
and national building regulations.
•
Soft furnishings, decorations and wall coverings etc. must not be placed
within 1.5 metres of the appliance and its outlets.
•
Be aware of curtains etc. that could be blown towards the appliance.
•
The fire is intended as a secondary heat source and should not be
used as a primary heat source
. Check that a primary heat source
(such as radiators) is present in the room. If insufficient primary heat is
being used there may be a build up of condensation.
•
The fire must not be used in rooms where the atmosphere is likely to
contain water or chemical vapours that may adversely affect the
appliance or its finish.
•
Do not use while painting or decorating, or in newly decorated rooms as
the residue can lead to unpleasant smells from the appliance. Always
cover or have the appliance removed while decorating.
•
This appliance does not contain Asbestos.
•
The fire is designed to be wall mounted and must not be recessed into a
fireplace opening.
•
The appliance has been designed to be installed onto a wall. It must be
placed on a non-combustible surface of minimum 12mm thickness. The
surface on which the appliance is to be mounted must be flat, level and
square to the back panel. Care should be taken with all wall coverings as
it may discolour them in time.
•
The fascia supplied with the appliance must be used.
•
The fire must be used in a room with adequate ventilation. It may be
required to open a window when using the appliance.