18
5. Reinstall the rear burner brass elbow by using a wrench.
6. Reinstall the rear burner rear cover, and heat shield.
5. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
6. Test all connections by brushing on an approved
noncorrosive leak detection solution. Bubbles will show a
leak. Correct any leak found.
7. The igniter battery is not factory installed. A “AA” size
alkaline battery is located in the accessory box on the grill
grate. Install battery at this time following the instructions
in “Replacing the Igniter Battery” section.
8. Go to “Check and Adjust the Burners” section.
A. Gas supply line
B. Shutoff valve “open” position
C.To grill
Gas Connection
1. Before making any connections, check to ensure the
natural gas inlet pressure falls between the allowable
range of 7" W.C. / 0.25 psi and 14" W.C. / 0.5 psi. If the
NG inlet pressure does not fall within this range, contact
your local gas supplier.
2. A combination of pipe fittings must be used to connect the
grill to the existing gas line.
The 10 ft (3.0 m) PVC flexible gas supply hose design
certified by CSA must be used.
Pipe-joint compounds suitable for use with Natural
gas must be used. Do not use Teflon
®†
tape.
There must be a certified manual shut-off valve in the
gas supply line near the grill for easy access.
3. Connect the brass connector on one end of the 10 ft (3.0
m) PVC flexible gas supply hose to the Natural gas
pressure regulator.
4. Connect the quick connector on the other end of the 10 ft
(3.0 m) PVC flexible gas supply hose to the rigid Natural
gas supply pipe.
Summary of Contents for 740-0788P
Page 10: ...5 6 7 8 9 10 1 3 4 2 10 x2 x3 x5 PACKAGE PARTS LIST x2...
Page 11: ...11 13 12 11 PACKAGE PARTS LIST TOOLS NEEDED HARDWARE PACKAGE LIST W5 32 32 x 2 5 screw...
Page 38: ...5 6 7 8 9 10 1 3 4 2 38 x2 x3 x5 Liste des pi ces de l emballage x2...
Page 58: ...58 Replacement Parts see Page 59 Pi ces de rechange voir Page 60...