MAXIMUM PRESSURES/TEMPERATURES

                      Polycarbonate Bowl      Metal Bowl

Metal Bowl with

DISPOSAL

Sight level

CLASS

TI

FILTERS

bar

°C

bar

°C

bar

°C

MF2

10

50

-

-

-

-

1 & 3

P050-05

IF2/D/A

10

50

17

80

17

70

1 & 2

P500-01

IC3/4/DA

10

50

17

80

17

70

1 & 2

P501-01

IXI

10

50

17

70

17

70

1 & 2

P057-01

SF3/A

-

-

17

80

17

70

1 & 3

P050-03

REGULATORS
MR1/2/3

21 bar 70°C : CONTROL RANGES : 0.2/2. 0.3/4, 0.7/9 bar

1 & 3

P051-01

IRI

20 bar 70°C : CONTROL RANGES : 0.2/3.5, 0.5/1 bar

1 & 2

P058-01

SR2

21 bar 70°C : CONTROL RANGES : 1.3 - 17.0 bar

1 & 3

P570-01

SR3

21 bar 70°C : CONTROL RANGES : 0.2/4, 0.3/9 bar

1 & 3

P570-03

FILTER REGULATORS
IP2/A/D

10

50

17

80

17

70

1 & 2

P510-01

RANGES : 0.2/3.5, 0.5/10 bar

MP2

10

50

-

-

-

-

1 & 3

P054-01

RANGES : 0.2/2.0, 0.3/4.0, 0.7/9.0 bar

MPC2

10

50

-

-

-

-

-

P054-04

RANGES : 0.2/2.0,.0.3/4.0, 0.7/9.0 bar

1 & 3

LUBRICATORS
ML3

10

50

-

-

-

-

1 & 3

P052-07

IL1

10

50

17

80

17

70

1 & 2

P059-01

SL3

-

-

17

80

17

70

1 & 3

P052-04

OTHER PRODUCTS
IFM2

10

50

-

-

-

-

1 & 2

P580-01

S.M.S.

-

-

17

70°C

-

-

1 & 3

P050-17

BALL

all to 15 bar & 45°C

VALVES (all)

(see performance graph on TI for full details)

1 & 4

P560-01

DRI-LINE

-

-

16

80°C

-

-

1 & 3

P050-07

DISPOSAL
1.

Some plastic and/or rubber components

2.

Main body Zinc - epoxy coated

3.

Main body Aluminium - epoxy coated

4.

Brass and Steel

5.

Electronic Components

Note
Customers are reminded that under UK and EC Health, Safety and Environmental Law, when
returning products to Spirax Sarco they must provide information on any hazards and the
precautions to be taken due to contamination residues or mechanical damage which may present
a health, safety or environmental risk. This information must be provided in writing including Health
and Safety data sheets relating to any substances identified as hazardous.

Summary of Contents for Spirax-Monnier MP

Page 1: ...mi nated compressed air 3 is directed to the inside of the bowl 5 by the multi bladed whirl disc 4 Thepreliminaryseparationallowsmost of the liquids and the larger solid particles to pass down into the sump 6 away from any turbulence The air is then filtered by a 5 micron element 7 before flowing past the main valve 8 of the regulator portion of the MP2 With the adjustment knob 1 rotated fully ant...

Page 2: ...nto contact with the bowl Certain compressor lu bricating oils also contain additives harmful to polycarbonate and where there is any doubt we recommend in the interest of safety that a bowl guard be fitted Spare parts AVAILABLE SPARE Bowl Assembly A B Element Set 5 micron pkt 3 B C Bowl Guard Assembly X Y Z Panel Bracket Mounting Ring D How to order Example 1 Element Set for Spirax Monnier Filter...

Page 3: ...imum pressure range of the main Control Spring The gauge will indicate the downstream or controlled pressure 4 Ensure that the Control Spring range for RegulatorsandFilter Regulatorsfullymeets the pressure requirements of the system 5 There are Maximum Operating Pressures andMaximumOperatingandEnvironmental Temperatures for each product These are shown in the table below 6 Adequatespaceshouldbepro...

Page 4: ...P054 04 RANGES 0 2 2 0 0 3 4 0 0 7 9 0 bar 1 3 LUBRICATORS ML3 10 50 1 3 P052 07 IL1 10 50 17 80 17 70 1 2 P059 01 SL3 17 80 17 70 1 3 P052 04 OTHER PRODUCTS IFM2 10 50 1 2 P580 01 S M S 17 70 C 1 3 P050 17 BALL all to 15 bar 45 C VALVES all see performance graph on TI for full details 1 4 P560 01 DRI LINE 16 80 C 1 3 P050 07 DISPOSAL 1 Some plastic and or rubber components 2 Main body Zinc epoxy ...

Reviews: