IM-S24-42
CTLS Issue 10
19
0
4
8 12 16
300
250
200
150
100
50
0
-50
0
4
8 12 16
400
300
200
100
0
-50
Notes:
1.
Where the process fluid temperature is sub-zero and the ambient temperature is below +5
°C, the external
moving parts of the valve and actuator must be heat traced to maintain normal operation.
2.
When selecting a valve with a bellows sealed bonnet, the pressure/temperature limits of the bellows
must be read in conjunction with the valve pressure/temperature limits shown in table below.
Body design conditions
PN40
Maximum design pressure
40 bar g @ 50
°C
Maximum design temperature
400
°C
Minimum design temperature
-50
°C
Maximum operating temperature
PTFE soft seat (G)
200
°C
Standard packing PTFE chevron
250
°C
PEEK seat (K and P)
Extended bonnet (E) with PTFE chevron
High temperature packing (H)
400
°C
Extended bonnet (E) with graphite packing
Note:
We recommend that an extended bonnet (E) with graphite packing is used where valve operation is
above 300
°C.
The product
must not
be used in this region.
Bellows D
Te
mp
er
atu
re
°C
Pressure bar g
Te
mp
er
atu
re
°C
Pressure bar g
Steam
saturation
curve
Steam
saturation
curve
Bellows C
Summary of Contents for Spira-trol K Series
Page 2: ...IM S24 42 CTLS Issue 10 2...
Page 53: ...IM S24 42 CTLS Issue 10 53 Fig 22 Balanced 3 19 4 6 16 31 Fig 21 15...
Page 57: ...IM S24 42 CTLS Issue 10 57 C1 C D1 D2 D B E G A H Soft seat arrangement C2 Fig 26 H1...
Page 61: ...IM S24 42 CTLS Issue 10 61 C2 B D4 D5 E G D F A H Soft seat arrangement Fig 28 H1...
Page 66: ...IM S24 42 CTLS Issue 10 66...
Page 67: ...IM S24 42 CTLS Issue 10 67...
Page 68: ...IM S24 42 CTLS Issue 10 68...