![Spirax Sarco CA44 Installation And Maintenance Instructions Manual Download Page 8](http://html1.mh-extra.com/html/spirax-sarco/ca44/ca44_installation-and-maintenance-instructions-manual_1348011008.webp)
IM-P148-37
ST Issue 3
8
Sizes and pipe connections
CA46
DN15 and DN20 flanged
CA46S
DN15, DN20, DN25, DN40 and DN50 flanged
Standard flanges are EN 1092 PN40 with DIN face-to-face dimensions and BS 1560 class
ASME 150 and ASME 300 and JIS / KS 20K with drilled and tapped bolt holes with
DIN face-to-face dimensions. PN and JIS / KS flanges will be provided with BSP balance
line and ASME flanges with an NPT balance line.
Limiting conditions
Maximum body design conditions
PN40
PMA - Maximum allowable pressure
40 bar g
(580 psi g)
TMA - Maximum allowable temperature
400
°
C
(752
°
F)
PMO - Maximum operating pressure
40 bar g
(580 psi g)
TMO - Maximum operating temperature
400
°
C
(752
°
F)
PMX - Maximum differential pressure
32 bar g
(464 psi g)
Minimum operating temperature
0
°
C
(32
°
F)
PN40
60 bar g (870 psi g)
Designed for a maximum
ASME 300
60 bar g (870 psi g)
cold hydraulic test pressure of:
ASME 150
30 bar g (435 psi g)
JIS / KS 20K 49 bar g (710.5 psi g)
2.3 CA46 and CA46S - Austenitic stainless steel
Fig. 3
CA46 and CA46S
DN15 and DN20
DIN flange
Fig. 4
CA46S
DN40 and DN50
DIN flange
Summary of Contents for CA44