![Spirax Sarco CA44 Installation And Maintenance Instructions Manual Download Page 6](http://html1.mh-extra.com/html/spirax-sarco/ca44/ca44_installation-and-maintenance-instructions-manual_1348011006.webp)
IM-P148-37
ST Issue 3
6
2.2 CA44 and CA44S - Carbon steel
Sizes and pipe connections
CA44
DN15 and DN20 flanged
CA44S
1" screwed BSP or NPT with BSP or NPT balance line.
1" socket weld BS 3799 class 3000 with NPT or socket weld balance line.
DN15, DN20, DN25, DN40 and DN50 flanged
Standard flanges are EN 1092 PN40 with DIN face-to-face dimensions and BS 1560 class
ASME 150, ASME 300 and JIS / KS 20K with extended face-to-face dimensions.
On request ASME 150 and ASME 300 flanges with drilled and tapped bolt holes with
DIN face-to-face dimensions can be provided. PN and JIS / KS flanges will be provided with
BSP balance line and ASME flanges with an NPT balance line.
Limiting conditions
Maximum body design conditions
PN40
PMA - Maximum allowable pressure
40 bar g
(580 psi g)
TMA - Maximum allowable temperature
400
°
C
(752
°
F)
PMO - Maximum operating pressure
40 bar g
(580 psi g)
TMO - Maximum operating temperature
400
°
C
(752
°
F)
PMX - Maximum differential pressure
32 bar g
(464 psi g)
0
°
C
(32
°
F)
Minimum operating temperature
Screwed
60 bar g (870 psi g)
Socket weld
60 bar g (870 psi g)
PN40
60 bar g (870 psi g)
Designed for a maximum
ASME 300
60 bar g (870 psi g)
cold hydraulic test pressure of:
ASME 150
30 bar g (435 psi g)
JIS / KS 20K 60 bar g (870 psi g)
Fig. 1
CA44 and CA44S
DN15 and DN20
DIN flange
Fig. 2
CA44S
DN40 and DN50
DIN flange
Summary of Contents for CA44