Manual Revision 4.1.2
need to turn the machine off to try again, or physically point your machine in a
direction that will achieve the desired results.
45 Second Safety (Feeder)
By default, your feeder is designed to turn off automatically after
approximately 25 seconds (can be up to 45 seconds) if no balls are fired. This
is to prevent balls firing unexpectedly at the user. However, sometimes this
feature can cause the feeder to stop, even when balls are firing. The solution
is to simply disable this feature, which you can do by following these steps:
1. Start with your machine off
2. Turn it on by pressing “power” and “down” simultaneously
3. You can now toggle this setting by pressing “up”.
4. Press “menu” to save the new setting.
Your machine will remember this setting for all future uses (until changed
again).
Feeder Speed Calibration
Please note, these instructions only apply to interval mode 1. Please see the
next heading “Interval Mode 1 and 2” to understand the difference.
Your machine should be able to fire one ball every 2 seconds at the fastest
interval. If you feel that it is not calibrated correctly, you can recalibrate it by
following these steps:
1. Start with the machine turned off
2. Turn it on by pressing “power” and “up” at the same time for 3-5
seconds.
3. You will see a screen showing "Interval 20" and "Feed Base 50"
(settings may vary).
4. You can adjust the feed base from 20 (slower) to 120 (faster) by using
the left and right arrow keys. This will alter the default speed when the
interval is set to 20 (the ideal setting is 30 balls per minute – one
carousel revolution in 10 seconds).
5. To save the new setting, simply press "menu".
6. Once saved, you can turn off the machine with the power button (then
turn it back on again).
Warning, if you increase this base speed too much, the throwing wheels will
not be able to recover quickly enough before a 2nd ball is fired when the
interval is at 20. This can cause speed problems. Please only alter this setting
if it is necessary and consult your dealer if you are unsure.
Interval Mode 1 and 2
By default, all machines from March 2017 are set with Interval Mode 2. Earlier
machines had Interval Mode 1 as the default.
Interval Mode 1:
The feeder motor will constantly spin, varying its speed