SPIN s.r.l.
Дата 02/02/2012
Верс. 02/12
30 / 40
6.0
RECHARGE OF GAS (INTERNAL BOTTLE CHARGE)
The amount of freon, which is present inside the internal bottle, has been charged in order to perform the fi-
nal inspection and the control of the station and it is sufficient to perform a complete charge. Therefore it is
advisable to charge the necessary gas using an external bottle when switching on the machine.
Total amount of gas suggested: 4-6 Kg
To charge the internal bottle select Gas Recharge and set the desired quantity.
Note: the machine is equipped with a safety device that checks the gas of quantity inside the internal
bottle; if you try to perform a recovery with the bottle with a quantity of gas inside esxceeding the
alalrm leve (10kg) on the display will appear “ERROR 4” and the messahe of full bottle. In this case
you can perform vacuuming and charging operations only until the quantity of gas inside the bottle
is less than 10kg.
If the quantity of gas inside the bottle is not sufficient (less than 1 kg), after the setting, the display will show
“ERROR 1” and the message of insufficient quantity of gas inside the bottle, in such a case you should follow
the instructions outlined ion “gas recharge”.
6.1
PRESSURE TEST OF THE A/C SYSTEM
The two high and low pressure taps
must to be closed
.
Press the key “
STOP
” on the keyboard.
Start the vehicle in gear of 1500 r.p.m.
Switch-on the A/C system.
Control the pressure on the gauges “A” and “B” according to the following table:
T. SURROUNDING
LOW PRESSURE
HIGH PRESSURE
°C 15
0,5
– 2,0
7,5
– 13
°C 20
0,5
– 2,5
10
– 16
°C 25
0,5
– 2,5
12
– 18
°C 30
0,5
– 3
12
– 20
- At the end of the test, disconnect the coupling from the a/c system, open the taps of the station and perform
the recovery of the gas
THE INTERNAL BOTTLE IS SUPPLIED WITH A MECHANICAL SAFETY VALVE
,
WHICH OPENS AUTOMATICALLY
,
WHEN THE PRESSURE RISES OVER
16
BAR
.
A SECOND VALVE
,
WHICH CAN BE REACHED MORE EASILY
,
IS
PLACED ON THE LEFT SIDE OF THE STATION
.
CHAP. 6
– USE OF THE STATION
Summary of Contents for OK CLIMA
Page 2: ...SPIN s r l 02 02 2012 02 12 2 40...
Page 4: ...SPIN s r l 02 02 2012 02 12 4 40 5 5 6 1 6 2 7 3 8 4 9 5 11 6 12 7 18 8 20...
Page 10: ...SPIN s r l 02 02 2012 02 12 10 40 5 6...
Page 11: ...SPIN s r l 02 02 2012 02 12 11 40 4 1 8 2 E F 3 4 5 RL 100 H 5 8 10 R134 21CR 9 G H 7 H G...
Page 13: ...SPIN s r l 02 02 2012 02 12 13 40 6 2 Enter C 6 3 Enter C 9 6 1 2 C 0 5 0 5 5...
Page 14: ...SPIN s r l 02 02 2012 02 12 14 40 6 4 ERR2 C 6 1 0 5 0 5 5 Enter C...
Page 18: ...SPIN s r l 02 02 2012 02 12 18 40 150 9 100 150 AV68I 300 B C 11 A B C 7 11 A B C AV68I...
Page 19: ...SPIN s r l 02 02 2012 02 12 19 40 100 150 2 12...
Page 21: ...SPIN s r l 02 02 2012 02 12 21 40...
Page 28: ...SPIN s r l 02 02 2012 02 12 28 40 Fig 6 Change of the printer paper Fig 5...