5. Troubleshooting
SPHERE
Portable Traffic Signals
Model:
ST-PS5
/ Technical Specifications, Instruction Manual and Warranty Card
33
5.1.3 Permanent Loss of Communication Between MASTER and SLAVES
in a Daisy Chain Operational Mode
The radio link in Daisy Chain operational mode can be disrupted permanently because of the following reasons:
MASTER or SLAVE units have not yet established radio link communication between them
MASTER or SLAVE units have established radio link communication between them, but the communication is still
faulty
If the radio link between MASTER and SLAVE units is disrupted for a period longer than 15 seconds:
The healthy units will display a
MAGENTA
LED on the SYSTEM INDICATOR/OPERATOR INTERFACE and all units will
immediately transition to FLASHING AMBER condition
The faulty unit will display a
RED
LED RADIO ERROR or WRONG CHANNEL SELECTED fault on the OPERATOR
INTERFACE and the unit will immediately transition to FLASHING AMBER condition
RED
RADIO ERROR or WRONG
CHANNEL SELECTED
RED
RADIO ERROR or WRONG
CHANNEL SELECTED
MAGENTA
SYSTEM INDICATOR
Displays on all
SLAVES.
Displays on a faulty
SLAVE only.
Displays on MASTER
and SLAVES.
MASTER is faulty.
MASTER and the
rest of the SLAVES
are OK.
Look for a SLAVE
with RADIO ERROR
or WRONG
CHANNEL
SELECTED fault.
Follow
SOLUTION
guide.
Follow
SOLUTION
guide.
Follow
SOLUTION
guide.
SOLUTION:
1.
Turn ON all units
2.
Move all units within range
3.
Make sure that the MASTER unit has SLAVE TOTAL programmed
4.
Make sure that the SLAVE units have SLAVE IDs programmed in a correct order from Id.1 to the last unit (e.g. ID.1,
ID. 2 and ID. 3 if the total number of SLAVEs is 3)
5.
Program the same channel on all units
6.
Enter the correct operational mode (Daisy Chain on MASTER and Daisy Chain on SLAVES)
7.
Check the battery status
8.
Reset all units (reconnect their batteries)
9.
Possible SYSTEM FAULT
10.
Possible broken antenna or faulty radio module
CALL SUPPORT
- If not resolved by the above.