background image

SPERRY INSTRUMENTS LIMITED LIFETIME WARRANTY

Subject to the exclusions and limitations detailed below, Sperry Instruments provides a limited lifetime warranty on products  

of its manufacture will be free from defects in materials and workmanship under normal use and service.

Limited

Limited means that Sperry Instruments warrants to the original purchasers of products from Sperry Instruments authorized distributors at the 

time of shipment such products shall be free of defects in material and workmanship while the tool is used under normal working conditions. 

Standard wear and tear, dulling over time, overloading, misuse, and acts of God are not covered under warranty. This warranty does not cover 

batteries, fuses, or test leads.

When a warranty claim arises, the purchaser must contact Sperry Instruments. If the defect comes under the terms of this  

limited warranty, Sperry Instruments will arrange, at its sole discretion, one of the following options: 

• Product will be replaced

The purchaser is solely responsible for determining the suitability of Sperry products for the purchaser’s use or resale, or for incorporating 

them into articles or using them in the purchaser’s applications. The distributor is authorized to extend the foregoing limited warranty to its 

original purchasers in connection with the sales of Sperry products, provided that such products shall not have been altered by the distributor. 

The distributor shall be fully responsible for any warranties the distributor makes to its purchasers which are broader or more extensive than 

Sperry’s limited warranty. 

Lifetime Warranty

Warranty Limitation: The forgoing warranties are exclusive and are in lieu of all other express and implied warranties whatsoever, including but 

not limited to implied warranties of merchantability and fitness for a particular purpose. The foregoing warranties do not cover ordinary wear 

and tear, abuse, misuse, overloading, alterations, products which have not been installed, operated or maintained in accordance with Sperry’s 

written instructions. Test leads, fuses, batteries and calibration are not covered under any implied warranty. “Lifetime” of products that are no 

longer offered by Sperry will be either repaired or replaced with an item of Sperry Instruments choice of similar value. Lifetime is defined as 5 

years after Sperry discontinued manufacturing the product, but the warranty period shall be at least ten years from date of purchase. Original 

proof of purchase is required to establish original ownership of product.

No warranty will be honored unless an invoice or other proof of purchase date is provided to Sperry Instruments. Hand written receipts or 

invoices will not be honored. 

©2019 ECM Industries, LLC All rights reserved.

- See more at: https://www.sperryinstruments.com/en/Resources/Warranty-Information

6

SPR_TL_087_0519

Sperry Instruments

800-645-5398

New Berlin, WI 53151

sperryinstruments.com

Summary of Contents for DM4A

Page 1: ... is set to DCV or ACV Pressing it will also switch between Hz and when the dial is set to Hz measurement 5 HOLD Button Press to lock and hold the value currently being displayed Press again to exit this mode 6 Rotary Switch Turn to power the meter on and off and select the desired measurement function To save battery power turn to the OFF position when the meter is not in use See ROTARY SWITCH sec...

Page 2: ... thoroughly before use 2 0 READ FIRST IMPORTANT SAFETY INFORMATION Read this operators manual thoroughly before using this multimeter This manual is intended to provide basic information regarding this meter and to describe common test procedures which can be made with this unit Many types of appliance machinery and other electrical circuit measurements are not addressed in this manual and should ...

Page 3: ... and feeders from the distribution panel to outlets CAT IV The circuit from the service drop to the service entrance and to the power meter and primary over current protection device distribution panel Avoid placing the meter in areas where vibration dust or dirt is present Do not store the meter in excessively hot humid or damp places This meter is a sensitive measuring device and should be treat...

Page 4: ...s potentiometers switches extension cords and fuses Note For measurements 1MΩ the meter may take a few seconds to stabilize reading This is normal for high resistance measurements When the input is not connected i e at open circuit OL will be displayed as an overrange indication 5 4 CONTINUITY To avoid damages to the Meter or to the devices under test disconnect circuit power and discharge all the...

Page 5: ...structions above to measure Hz and 6 0 BATTERY REPLACEMENT To avoid false readings which could lead to possible electric shock or personal injury replace the battery as soon as the battery indicator 8 8 MAX MIN appears 1 Disconnect the connection between the test leads and the circuit under test 2 Turn the meter power off 3 Remove the screw from the back of the meter Lift off the back cover 4 Lift...

Page 6: ...h products shall not have been altered by the distributor The distributor shall be fully responsible for any warranties the distributor makes to its purchasers which are broader or more extensive than Sperry s limited warranty Lifetime Warranty Warranty Limitation The forgoing warranties are exclusive and are in lieu of all other express and implied warranties whatsoever including but not limited ...