background image

14

13

around the home.

ALWAYS REMEMBER THAT

CONTINUITY CHECKS ARE TO BE MADE
WITH THE POWER TO THE CIRCUIT
TURNED OFF

. Polarity of the test leads is not a

factor in making continuity checks.

7.1 Extension Cords

Unplug the cord. Set the function/range switch to
the Rx1K position. Touch one of the test leads to
one of the metal prong ends of the cord, and
insert the other test lead in either one of the
receptacle slots on the other end of the cord,
making sure the test lead is making good contact
with the receptacle (see fig. 4). If the needle 
indicator does not move to -0- ohms, insert the
test lead into the other receptacle slot, again
making sure of good contact. If the needle 
indicator still does not move the cord has a break
and should be replaced.

7.2 Fuses

Note: With the power OFF, always remove a
fuse from its socket before testing it. With 
cartridge fuses, touch the test leads to each
end of the fuse (see fig. 5). If the fuse is good,
the needle indicator will move to -0- ohms. If not,
replace the fuse. On plug-type fuses, touch the
the test leads on the bottom contact and the
other on the threaded metal contact (see fig. 6).

7.3 Switches

Cut off the power source to the switch. If 
necessary, remove the switch. Turn the switch to
the ON position and touch the test leads to the
switch terminals (see fig. 7). If the switch is
good, the needle indicator will move to -0-
ohms. If not, replace the switch. On other
switches such as three-way light switches or
double pole double throw (ON-OFF-ON) 
switches, each ON position will need to be 
tested. Alternate the test leads between the
switch terminals to determine which two 
terminals control that ON position.

8. Decibel Measurement

The decibel feature of this multimeter is for 
transistor gain measurement in electronic cir-
cuits and should not be confused with audio
decibels. This function is used primarily by elec-
tronics technicians to measure the power gain
in transistors, and is rarely encountered in home 
project applications.

Figure 4

Figure 6

Figure 5

Figure 7

HSP5 3-09 manual.qxp  5/8/09  9:57 AM  Page 14

Summary of Contents for GMT-312

Page 1: ...ual Read this owners manual thoroughly before use and save HSP5 HSP5 3 09 manual qxp 5 8 09 9 57 AM Page 1 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at...

Page 2: ...or the homeowner hobbyist and professional needing to make electrical and electronic equipment measurements 1 1 Meter Functions Needle Analog Scale Mechanical Zero Adjust Screw Zero Ohms Adjust ment I...

Page 3: ...m max Decibels 20dB to 56dB on AC voltage ranges Accuracy DC voltage mA 4 full scale of range AC voltage 5 full scale of range Resistance 4 arc of scale length Sensitivity 2000 ohms per volt DC and AC...

Page 4: ...et the function range switch to WARNING WARNING 6 5 the appropriate setting for greater accuracy 2 Avoid placing the meter in areas where vibration dust or dirt are present Do not store the meter in e...

Page 5: ...n range switch to the ohms Rx1K position Short the test leads together and the needle indicator should deflect to the right side of the scale Keep the test leads shorted together while simultaneously...

Page 6: ...1 Common DC Milliamperage Measurements It is important to point out that milliamps can also be expressed as thousandths of an Ampere therefore 150 milliamps is 150 thousandths of one Amp The 150mA fun...

Page 7: ...nce and continuity testing POWER MUST BE OFF 1 Fully seat the test leads in the input jacks black lead red lead 2 Set the function range switch to the Rx1K position resistance indicated multiplied by...

Page 8: ...fuse is good the needle indicator will move to 0 ohms If not replace the fuse On plug type fuses touch the the test leads on the bottom contact and the other on the threaded metal contact see fig 6 7...

Page 9: ...uses GB model GF 0306 4 Carefully replace the back cover and tighten the screw Do not overtighten as this may strip the threads in the meter housing 10 Warranty 1 YEAR WARRANTY limited solely to repai...

Reviews: