Light Meter

850004

 

Instruction Manual

Summary of Contents for 850004

Page 1: ...1 Bluetooth Light Meter 850004 Instruction Manual...

Page 2: ...OCEDURES 5 SELECT LUX FOOT CANDLES 5 SELECT MEASURMENT RANGE 5 BACKLIGHT 6 HOLD FUNCTION 6 MAX MIN FUNCTION 6 AUTO POWER OFF 7 BLUETOOTH COMMUNICATIONS 8 BATTERY REPLACEMENT 11 SPECTRAL SENSITIVITY CH...

Page 3: ...imum hold peak and data hold functions The meter offers the convenience of Bluetooth for wireless communication with free iOS and Android Apps Results can also be remotely viewed on your smart phone i...

Page 4: ...4 1 2 3 4 5 7 6 PANEL DESCRIPTION 1 Photo Diode 2 LCD Display 3 HOLD button 4 MAX MIN button 5 Power button 6 Range Lux FC button 7 Bluetooth button...

Page 5: ...urce you wish to measure SELECT LUX FOOT CANDLES Press the red button for 2 seconds to toggle between Lux and Foot Candle Ranges SELECT MEASURMENT RANGE Press the red button to select auto range or ma...

Page 6: ...urn the illuminated display on off HOLD FUNCTION With the meter on press the HOLD button to display HOLD and the last reading Press HOLD again to exit this function MAX MIN FUNCTION Max Min readings a...

Page 7: ...on reaching lower readings 3 Press the MAX MIN button again to exit Max Min mode The current reading is now displayed and continually updated AUTO POWER OFF 1 If no buttons are pushed for about 10 mi...

Page 8: ...Connect Device on the APP 4 Now choose 850004 from the device list that now appears The meter will immedi ately begin displaying a real time graph of your meter s readings Saving your results 5 To beg...

Page 9: ...wish to view A graph of the entire record will now appear Press on the lower right to see the data including recording times maximum minimum and average readings 7 saved data file graph enables you to...

Page 10: ...rt your Hi and Low alarm values 4 Repeat steps 3 4 for additional alarm parameters you wish to set for your meter 5 Use the Alarm switch at the bottom to enable disable the alarm for the parameter sho...

Page 11: ...the battery compartment and insert a fresh 9V battery Replace the cover SPECTRAL SENSITIVITY CHARACTERISTIC The Photo diode and filters conform very closely to the spectral sensitivity character istic...

Page 12: ...igits 2500 Lux 10 rdg 10 digits 2500 Lux Operating Environment 32 to 104 F 0 to 40 C 10 to 80 RH Storage Environment 14 140 F 10 C 50 C 0 to 80 RH Power One 9V Battery Low Battery will flash when batt...

Page 13: ...13 OPTIONAL ACCESSORIES 840093 Field Tripod...

Page 14: ...14 NOTES...

Page 15: ...15 NOTES...

Page 16: ...ientific product will be substituted if available This warranty does not cover damage resulting from accident misuse or abuse of the product To obtain warranty service ship the unit postage prepaid to...