1.4 SERVICING REQUESTS
For any information regarding the use, maintenance and installation, please contact the Spencer Customer Care Service on 0039 0521 541111 -
Fax 0039 0521 541222 - e-mail: [email protected] or write to Spencer Italia Srl - Strada Cavi, 7 - 43044 Collecchio (Parma) ITALY.
1.5 DEMOLITION
Follow the current regulations.
1.6 LABELLING
The serial number as indicated below can be found on each appliance and must not be removed or covered. In order to facilitate assistance
please indicate or communicate the serial number (SN) or lot number (LOT) on the label.
2.3 PHYSICAL REQUIREMENTS OF THE OPERATOR
This device, during the loading / unloading procedure, requires not less then two operators which are strong, balanced and which have good
sense. The capacity of every operator must be considered before determining his role in the employment of the devcie.
2
WARNINGS
2.1 GENERAL WARNINGS
•
Before carrying out any kind of operation on the product, the operator must carefully read the enclosed instructions, paying particular attention to the
correct safety precautions and to the procedures to be followed for installation and for correct use.
•
In the case of any doubts as to the correct interpretation of the instructions, please contact Spencer Italia Srl, for any necessary clarifications.
•
Regularly check the appliance. Carry out the prescribed maintenance in order to keep the appliance in good condition and to guarantee correct func-
tioning and a long life.
•
In the case of any abnormalities or damage to the appliance, which could jeopardize the functioning, and the safety, the appliance must be immedia-
tely removed from service.
•
Do not alter or modify in any way the appliance; any such interference could cause malfunctions and injury to the patient and/or rescuer.
•
The appliance must not in any way be tampered with, in such cases all responsibility will be denied for any malfunctions or eventual injuries caused
by the appliance itself.
•
Who modifies or has modified, prepares or has prepared appliances in such a way that they no longer serve the purpose for which they were inten-
ded, or no longer supply the intended service, must satisfy the valid conditions for the introduction onto the market.
•
Ensure that all the necessary precautions are taken in order to avoid hazards that can arise as the result of contact with blood or body fluids.
•
Handle with care.
2.2 SPECIFIC WARNINGS
•
The product may only be used by trained personnel.
•
Never exceed the maximum capacity as described in this User's Manual.
•
Do not use if the weight has not been distributed correctly.
•
Pay attention to possible obstacles on the way to drive.
•
In case of anomalies or damages that may compromise the functionality and the safety of the device, take the device out of service immediately.
1 GENERAL INFORMATION
1.1 AIM AND CONTENTS
The aim of this manual is to supply all the information necessary so that the client, apart from attaining an adequate use of the appliance, will
also be capable of using the instrument in the most autonomous and secure way possible. This includes information regarding technical
aspects, functioning, maintenance, spare parts and safety.
1.2 CONSERVATION OF THE INSTRUCTION MANUAL
The instruction and maintenance manual must be kept with the product, inside the specially provided container and above all, away from any
substances or liquids which could compromise perfect legibility.
1.3 SYMBOLS USED
Thank-you for choosing a Spencer product
SYMBOL
See instructions for use.
3 DESCRIPTION OF PRODUCT
3.2 MAIN COMPONENTS
1. n° 2 turning wheels Ø200 mm.
2. n° 2 turning wheels Ø200 mm with brakes. The braking system
blocks both the turning movement of the wheel and the turning of the
entire wheel unit.
3. n° 2 turning supports, made out of a rolling system, two handles and
a blocking lever, which allow quick and safe movement of the coffin
during loading, unloading and working.
4. n° 4 extensions, integrated in the frame, but removable in order to
obtain the minimum height (550mm)
5. n° 4 lever in order to ad just the intermediate heights
3.1 INTENDED USE
The Z4002 is a work bench which optimizes the movement and treatment of coffins, offering to the operator a correct ergonomic position in any situa-
tion.
2.4 CONTRAINDICATIONS AND SIDE EFFECTS
The appliance, if used as described in the manual, does not present any contraindications in use.
Fig.1