Unit Description 

 

The XMPF10N5/24 unit consists of one chassis containing the high voltage power supply.  
The dimensions are 170mm x 70mm x 30mm 
 
The unit is designed for operation from 24Vdc ± 10%. The maximum rated input current is 500mA. 
 
The unit provides an HV Cathode output rated at -10kV, 5W. With a floating filament intended to drive an X-
ray tube with a grounded anode, rated at 0V to 3.5Vac referenced to the Cathode Output, 0.42A max. 
 
All control and monitoring is accomplished via 

a 15 way ‘D’ connector which also provides input power to the 

unit.  
 

Operating Temperature is 5

C to +40

C ambient for normal operation. 

 
The mass of the module is nominally 2kg. 

 
 

Safety 

 

The HV output of the unit is hazardous and the conditions of this manual must be complied with to maintain 
safety. Operating the unit in a manner not specified in this manual may impair the protection against electric 
shock provided by the unit.  
 
The unit is contained in an earthed  case, the system protective earth shall be provided to the chassis. The 
case of the unit shall be properly bonded to the main protective earth termination in the end product.  
 
The unit has been evaluated for use in a Pollution Degree 2, Installation Category II environment. 
 

Consideration should be given to conducting the following tests with the unit installed in the end product:   
 

 

 

Dielectric Voltage Withstand Test, between live parts of the unit and the end product chassis. 

 

Permissible Limits Tests with the unit installed in the end product. 

 

Temperatures on power electronic components, transformer windings and accessible surfaces. 

 

There is no relevance to a risk assessment carried out as part of the CE testing on the HV unit. It is 
recommended that a full assessment is carried out in the end application. 

 
 
 

Summary of Contents for XMPF10N5/24

Page 1: ... INSTALLATION INSTRUCTIONS Document Number 81234 4 Issue A Date 23 01 18 Issuing Authority I 5650 Checked Approved Tel 44 0 1798 873986 Fax 44 0 1798 872479 E mail hvsales spellmanhv co uk Broomers Park Broomers Hill Lane Pulborough W Sussex RH20 2RY ...

Page 2: ...tions unless equipment is turned off and the capacitance of both the load and power supply are grounded Allow adequate time for discharge of internal capacitance of the power supply Do not ground yourself or work under wet or damp conditions Servicing Safety Maintenance may require removing the Instrument cover with the power on Servicing should only be done by qualified personnel aware of the haz...

Page 3: ...and the conditions of this manual must be complied with to maintain safety Operating the unit in a manner not specified in this manual may impair the protection against electric shock provided by the unit The unit is contained in an earthed case the system protective earth shall be provided to the chassis The case of the unit shall be properly bonded to the main protective earth termination in the...

Page 4: ...arranty 3 2 Mechanical Installation The unit should only be used in a Pollution Degree 2 Installation Category II environment The input and output connectors are not intended for field connections and should only be connected to internal wiring in the end product The unit is intended for use as a component and no surface of the unit should be accessible in the end product 3 3 Electrical Installati...

Page 5: ...de voltage program input 0 10V input 9 Cathode voltage monitor 0 10V output 10 Emission current monitor 0 10V output 11 Filament current monitor 0 10V output 12 Emission current program input 0 10V input 13 Emission current program output 0 10V from internal pre set 14 Signal ground 15 Pre set maximum filament current set value 4 2 Output The HV output is a flying lead consisting of 2 Reynolds 18k...

Reviews: