2.5
CONFIGURATION SWITCH
Since a 200-C488 interface may be used with any Spellman Series 205A/210 high voltage power supply,
the 200-c488 must be configured to implement the correct data formats for each supply. After removing
the top cover of the 200-C488, a six position DIP switch may be seen on the large printed circuit board.
Table 2.1 shows the correct setting for each power supply.
As with the GIPB switch the configuration switch is only at power-on and if it is to be changed, the unit
must be turned off and then back on, or reset. Figure 2.2 is a representation of the switch, as it would be
seen on the PCB.
FIGURE 2.2
Table 2.1
CONFIGURATION SWITCH SETTINGS BY MODEL
SWITCH POSITION
MODEL:
1
2
3
4
5
6
205A/B-01R
0
0
0
0
0
0
205A/B-03R
0
0
0
0
0
1
205A/B-05R
0
0
0
0
1
0
205A/B-10R
0
0
0
0
1
1
205A/B-20R
0
0
0
1
0
0
205A/B-30R
0
0
0
1
0
1
205A/B-50R
0
0
0
1
1
0
210-01R
0
0
0
1
1
1
210-01.5R
0
1
1
1
1
0
210-02R
0
1
0
0
0
0
210-03R
0
0
1
0
0
0
210-05R
0
0
1
0
0
1
210-10R
0
0
1
0
1
0
210-20R
0
0
1
0
1
1
210-30R
0
0
1
1
0
0
210-50R
0
0
1
1
0
1
210-75N/P
0
0
1
1
1
0
210-100N/P
0
0
1
1
1
1