34
to "1040", "Window H Start" to "0", "Window V Start" to "0", "Splice Mode" to "
Unequal", "H Total Width" to "3640", "V Total Height" to "1040", "H splice Start"
to "1872", and "V Splice Start" to "0".
PIP Mode Setting
PIP adopts the digital technology to realize concurrent display of two
programs, allowing one or more compressed sub-screens to be displayed on the
main screen so that you can monitor channels while watching the main screen.
PIP Parameter Setting
Press PIP (this switch is turned on when the PIP button is lighted up), enter
"Window & Crop", and change "Output Channel" to "PIP", "Window Adjust" to
"Enable", " Window H Start" to "364", " Window V Start" to "250", " Window H
Width" to "480", and " Window V Height" to "320". The following figure shows
the adjustment result.
Note: Only DVI1 and DVI2 supports PIP output.
Input DVI1
H Start
364
V Start
250
H Width 480
V Height 320
320
Figure 18-4
e 18-4