© 2018 All Rights Reserved.
7
General Maintenance
and Storage
Troubleshooting
PROBLEM
PROBABLE CAUSE
SOLUTION
Motor does not start
• Switch not on
• No power
• Bad connection
• Internal pump pressure
switch senses high pressure
• Failed switch
• Failed motor/pump
• Blown fuse
• Turn switch on
• Check for power at outlet
• Check for loose wire connections
• Ensure output of pump is
not blocked
• Replace
• Replace
• Replace
Water does not circulate
• Pump not working
• Liquid level too low
• Replace pump head or clean
and repair
• Make sure liquid level is above
inlet hose strainer in bucket
while circulating
Liquid spewing from unit
• Too much descaling solution
• Stop adding acid.
• Remove some liquid, neutralize
and discard according local
regulations
SC-DS-05
Pump Type
Diphragm
Motor
1/6 HP, 115v. 1 Amps 50/60 Hz
(1/6 HP, 220 V, 0.6 Amps, 50/60 Hz)
Maximum Flow
3 GPM [11 Lpm]
Maximum Head
69 Feet
Motor Rating
Intermittent
Temperature Range
0° F to 130° F+ (54°C)
Dimensions
Height 19”, Diameter 14”, Weight: 11 lbs
[with bucket]
Capacity
4 gal [15 L]
Hose Threaded Connections
Female Garden Hose
Technical Data