WARNING

This gas appliance contains or produces a chemical
or chemicals which can cause death or serious ill-
ness and which are known to the State of California
to cause cancer, birth defects, or other reproductive
harm. To reduce the risk from substances in the fuel
or from fuel combustion, make sure this appliance is
installed, operated, and maintained according to the
instructions in this manual.

W115

WARNING

To reduce the risk of fire, DO NOT use plastic or thin
foil ducting to exhaust the dryer.

W354

WARNING

To reduce the risk of fire, the exhaust duct and
weather hood MUST be fabricated of a material that
will not support combustion. Rigid or flexible metal
pipe is recommended for a clothes dryer.

W048

DRY1915N_SVG

2

1

1.  

Correct

2.  

Incorrect

Figure 4

• DO NOT use plastic, thin foil or type B ducting. Rigid metal

duct is recommended.

• Locate dryer so exhaust duct is as short as possible.

• Be certain old exhaust ducts are cleaned before installing your

new dryer.

• Use 4 inch [102 mm] diameter rigid or flexible metal duct.
• The male end of each section of duct must point away from

the dryer.

• Use as few elbows as possible.
• Use of duct tape or pop-rivets on all seams and joints is rec-

ommended, if allowed by local codes. DO NOT use sheet
metal screws or fasteners on exhaust pipe joints which extend
into the duct and catch lint.

• Ductwork that runs through unheated areas must be insulated

to help reduce condensation and lint build-up on pipe walls.

• In mobile home installations, dryer exhaust duct must be se-

cured to mobile home structure.

• Dryer exhaust duct MUST NOT terminate under mobile

home.

• Exhaust duct must not be connected to any other duct, vent, or

chimney.

• Dryer exhausts 220 cfm (measured at back of dryer).
• DO NOT install flexible duct in concealed spaces, such as a

wall or ceiling.

• Static pressure in exhaust duct should not be greater than 0.6

inches water column [1.5 cm water column], measured with
manometer placed on exhaust duct 2 feet [610 mm] from dry-
er (check with dryer running and no load).

• Exhausting dryer in hard-to-reach locations can be done by

installing 521P3 Flexible Metal Vent Kit (available as option-
al equipment at extra cost).

• Sufficient make-up air must be supplied to replace the air ex-

hausted by the dryer. The free area of any opening for outside
air must be at least 40 in.

2

 [1016 mm

2

].

• Failure to exhaust dryer properly will void warranty.

NOTE: Venting materials are not supplied with the dry-
er (obtain locally).

IMPORTANT: DO NOT block the airflow at the bottom
of the dryer’s front panel with laundry, rugs, etc. Block-
age will decrease airflow through the dryer, thus reduc-
ing the efficiency of the dryer.

 Exhaust Direction

The dryer can be exhausted to the outdoors through the back, left,
right or bottom of the dryer. EXCEPTION: Gas dryers cannot be
vented out the left side because of the burner housing.

Dryer is shipped from factory ready for rear exhaust.

Exhausting the dryer through sides or bottom can be accomplish-
ed by installing a Directional Exhaust Kit, 528P3, available as
optional equipment at extra cost.

 Exhaust System

For best drying results, recommended maximum length of ex-
haust system is shown in 

Table 2 

.

Installation

  12

©

 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT

  Part No. 514319R1

www.goedekers.com

Summary of Contents for ADEE8RGS

Page 1: ...tions for Dryers Original Instructions Keep These Instructions for Future Reference If this machine changes ownership this manual must accompany machine www speedqueen com Part No 514319R1 October 201...

Page 2: ...www goedekers com...

Page 3: ...e in your building Clear the room building or area of all occu pants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s in structions If you cannot reach your gas sup...

Page 4: ...reduce the risk of severe injury or death follow all installation instructions Save these instructions W894 WARNING FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids i...

Page 5: ...re Plug 15 Connecting Power Cord with Four Wire Plug 17 Reverse Door if Desired 18 Wipe Out Inside of Dryer 20 Plug In the Dryer 20 Electric Dryer 20 Gas Dryer 20 Recheck Steps 21 Check Heat Source 21...

Page 6: ...in 391 mm F 15 44 in 392 mm G 26 875 in 683 mm H 4 in 102 mm I 0 4 in 10 mm J 28 in 711 mm K 4 5 in 114 mm L 8 in 203 mm M 23 5 in 597 mm NOTE Exhaust openings are 4 inch 102 mm metal ducting With le...

Page 7: ...91 mm F 15 44 in 392 mm G 2 8 in 70 mm H 2 3 in 60 mm I 26 875 in 683 mm J 4 in 102 mm K 0 4 in 10 mm L 28 in 711 mm M 4 5 in 114 mm N 8 in 203 mm O 23 5 in 597 mm NOTE Exhaust openings are 4 inch 102...

Page 8: ...e of the dryer 7 Plug in the dryer 8 Recheck steps 9 Start and run the dryer in a heat setting to verify dryer is heat ing Position and Level the Dryer 1 Install dryer before washer This allows room f...

Page 9: ...DRY2662N_SVG 3 1 2 1 Dryer Base 2 Level 3 Leveling Leg Figure 2 Installation Part No 514319R1 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 9 www goedekers com...

Page 10: ...2664N_SVG 1 C A D E H 3 Front View Closet Door DRY2637N_SVG F F 2 G 1 Closet Door 2 Centered Air Openings G 2 Openings minimum 3 Outer Wall of Enclosure Figure 3 Installation 10 Copyright Alliance Lau...

Page 11: ...y connection 6 inches 152 mm is recommended when venting through rear of unit Table 1 IMPORTANT In mobile home installations gas dryers MUST be permanently attached to the floor at the time of install...

Page 12: ...ructure Dryer exhaust duct MUST NOT terminate under mobile home Exhaust duct must not be connected to any other duct vent or chimney Dryer exhausts 220 cfm measured at back of dryer DO NOT install fle...

Page 13: ...1 4 in 102 mm D802I_SVG 1 1 2 5 in 64 mm Maximum length of 4 in 102 mm diameter rigid metal duct 0 65 feet 19 8 m 55 feet 16 8 m 1 55 feet 16 8 m 47 feet 14 3 m 2 47 feet 14 3 m 41 feet 12 5 m 3 36 f...

Page 14: ...t 915 m the nat ural gas valve spud orifice size must be reduced to ensure com plete combustion Refer to Table 3 Natural Gas Altitude Adjustments Altitude Orifice Size Part No feet m No inches mm 3000...

Page 15: ...function or breakdown the earth ground will reduce the risk of electric shock by providing a path of least resistance for electric current The cord kit must be equipped with a cord having an equipment...

Page 16: ...2 13 10 11 7 6 1 14 1 A typical 30 Amp Three Wire Receptacle NEMA Type 10 30R 2 120 12 V A C 3 240 12 V A C 4 Intermediate Fuse Box may be omitted if service entrance box is fused 5 Wall Receptacle 6...

Page 17: ...of the earth ground connection before plugging the cord into an outlet Use an acceptable indicating device connected to the center earth ground pin of the plug and the green screw on the back of the c...

Page 18: ...inal b Black wire to L2 terminal c White wire to Neutral terminal NOTE When installing the white wire loop the free eyelet end of the earth ground to neutral wire re moved in Step 3 and attach along w...

Page 19: ...RY1916N_SVG B A Figure 17 4 Rotate door panel 180 degrees as shown D273P_SVG Figure 18 5 Remove door strike from door liner and reinstall on opposite side DRY1917N_SVG Figure 19 6 Insert liner under f...

Page 20: ...d with a 3 prong earth ground plug Refer to serial plate for specific electrical requirements NOTE The wiring diagram is located in the control hood WARNING To reduce the risk of fire electric shock s...

Page 21: ...d and should be plugged directly into a protective earth ground three prong receptacle Do not cut or remove the earth ground prong from this plug W823 WARNING Improper connection of the equipment eart...

Page 22: ...lazy yellow tipped flame indicates lack of air A harsh roar ing very blue flame indicates too much air Adjust the air shutter as follows a Loosen the air shutter lockscrew b Turn the air shutter to t...

Page 23: ...www goedekers com...

Page 24: ...AS ONLY Connect Gas Sup ply Pipe Check for Gas Leaks D233I_SVG1 7 Plug In the Dryer Electric D275I_SVG1 Gas D254I_SVG CHECK CHECK 4 ELECTRIC ONLY Connect Electrical Cord D679I_SVG1 8 Recheck Steps CHE...

Reviews: