Speed Queen ADEE8RGS Original Instructions Manual Download Page 20

8.  

Using screwdriver, remove two door plugs, and reinstall on
opposite side of door opening.

D317S_SVG

Figure 22

9.  

Reinstall four hinge attaching screws, removed in Step 1.

D606I_SVG

Figure 23

 Wipe Out Inside of Dryer

Before using dryer for the first time, use an all-purpose clean-
er, or a detergent and water solution, and a damp cloth to re-
move shipping dust from inside dryer drum.

D604I_SVG

Figure 24

 Plug In the Dryer

This appliance is to be supplied through a residual current device
(RCD) having a rated residual operating current not exceeding 30
mA.

 Electric Dryer

Connect the dryer to an electrical power source. Refer to Connect
Electrical Plug section for information on connecting power cord.

Connect to 30 Amp Circuit

D275I_SVG2

Figure 25

 Gas Dryer

Dryer requires 120 Volt, 60 Hertz electrical supply and comes
equipped with a 3-prong earth/ground plug. Refer to serial plate
for specific electrical requirements.

NOTE: The wiring diagram is located in the control
hood.

WARNING

To reduce the risk of fire, electric shock, serious in-
jury or death, all wiring and grounding MUST con-
form with the latest edition of the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1, and such local regulations as
might apply. It is the customer’s responsibility to
have the wiring and fuses installed by a qualified
electrician to make sure adequate electrical power is
available to the dryer.

W521

When plugging in the dryer:

• DO NOT overload circuits.
• DO NOT use an extension cord.
• DO NOT use an adapter.
• DO NOT operate other appliances on the same circuit. Use

separately fused 15 Amp circuits.

The dryer is designed to be operated on a separate branch, polar-
ized, three-wire, effective earth/ground, 120 Volt, 60 Hertz, AC

Installation

  20

©

 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT

  Part No. 514319R1

www.goedekers.com

Summary of Contents for ADEE8RGS

Page 1: ...tions for Dryers Original Instructions Keep These Instructions for Future Reference If this machine changes ownership this manual must accompany machine www speedqueen com Part No 514319R1 October 201...

Page 2: ...www goedekers com...

Page 3: ...e in your building Clear the room building or area of all occu pants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s in structions If you cannot reach your gas sup...

Page 4: ...reduce the risk of severe injury or death follow all installation instructions Save these instructions W894 WARNING FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids i...

Page 5: ...re Plug 15 Connecting Power Cord with Four Wire Plug 17 Reverse Door if Desired 18 Wipe Out Inside of Dryer 20 Plug In the Dryer 20 Electric Dryer 20 Gas Dryer 20 Recheck Steps 21 Check Heat Source 21...

Page 6: ...in 391 mm F 15 44 in 392 mm G 26 875 in 683 mm H 4 in 102 mm I 0 4 in 10 mm J 28 in 711 mm K 4 5 in 114 mm L 8 in 203 mm M 23 5 in 597 mm NOTE Exhaust openings are 4 inch 102 mm metal ducting With le...

Page 7: ...91 mm F 15 44 in 392 mm G 2 8 in 70 mm H 2 3 in 60 mm I 26 875 in 683 mm J 4 in 102 mm K 0 4 in 10 mm L 28 in 711 mm M 4 5 in 114 mm N 8 in 203 mm O 23 5 in 597 mm NOTE Exhaust openings are 4 inch 102...

Page 8: ...e of the dryer 7 Plug in the dryer 8 Recheck steps 9 Start and run the dryer in a heat setting to verify dryer is heat ing Position and Level the Dryer 1 Install dryer before washer This allows room f...

Page 9: ...DRY2662N_SVG 3 1 2 1 Dryer Base 2 Level 3 Leveling Leg Figure 2 Installation Part No 514319R1 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 9 www goedekers com...

Page 10: ...2664N_SVG 1 C A D E H 3 Front View Closet Door DRY2637N_SVG F F 2 G 1 Closet Door 2 Centered Air Openings G 2 Openings minimum 3 Outer Wall of Enclosure Figure 3 Installation 10 Copyright Alliance Lau...

Page 11: ...y connection 6 inches 152 mm is recommended when venting through rear of unit Table 1 IMPORTANT In mobile home installations gas dryers MUST be permanently attached to the floor at the time of install...

Page 12: ...ructure Dryer exhaust duct MUST NOT terminate under mobile home Exhaust duct must not be connected to any other duct vent or chimney Dryer exhausts 220 cfm measured at back of dryer DO NOT install fle...

Page 13: ...1 4 in 102 mm D802I_SVG 1 1 2 5 in 64 mm Maximum length of 4 in 102 mm diameter rigid metal duct 0 65 feet 19 8 m 55 feet 16 8 m 1 55 feet 16 8 m 47 feet 14 3 m 2 47 feet 14 3 m 41 feet 12 5 m 3 36 f...

Page 14: ...t 915 m the nat ural gas valve spud orifice size must be reduced to ensure com plete combustion Refer to Table 3 Natural Gas Altitude Adjustments Altitude Orifice Size Part No feet m No inches mm 3000...

Page 15: ...function or breakdown the earth ground will reduce the risk of electric shock by providing a path of least resistance for electric current The cord kit must be equipped with a cord having an equipment...

Page 16: ...2 13 10 11 7 6 1 14 1 A typical 30 Amp Three Wire Receptacle NEMA Type 10 30R 2 120 12 V A C 3 240 12 V A C 4 Intermediate Fuse Box may be omitted if service entrance box is fused 5 Wall Receptacle 6...

Page 17: ...of the earth ground connection before plugging the cord into an outlet Use an acceptable indicating device connected to the center earth ground pin of the plug and the green screw on the back of the c...

Page 18: ...inal b Black wire to L2 terminal c White wire to Neutral terminal NOTE When installing the white wire loop the free eyelet end of the earth ground to neutral wire re moved in Step 3 and attach along w...

Page 19: ...RY1916N_SVG B A Figure 17 4 Rotate door panel 180 degrees as shown D273P_SVG Figure 18 5 Remove door strike from door liner and reinstall on opposite side DRY1917N_SVG Figure 19 6 Insert liner under f...

Page 20: ...d with a 3 prong earth ground plug Refer to serial plate for specific electrical requirements NOTE The wiring diagram is located in the control hood WARNING To reduce the risk of fire electric shock s...

Page 21: ...d and should be plugged directly into a protective earth ground three prong receptacle Do not cut or remove the earth ground prong from this plug W823 WARNING Improper connection of the equipment eart...

Page 22: ...lazy yellow tipped flame indicates lack of air A harsh roar ing very blue flame indicates too much air Adjust the air shutter as follows a Loosen the air shutter lockscrew b Turn the air shutter to t...

Page 23: ...www goedekers com...

Page 24: ...AS ONLY Connect Gas Sup ply Pipe Check for Gas Leaks D233I_SVG1 7 Plug In the Dryer Electric D275I_SVG1 Gas D254I_SVG CHECK CHECK 4 ELECTRIC ONLY Connect Electrical Cord D679I_SVG1 8 Recheck Steps CHE...

Reviews: