To prevent backdraft when dryer is not in operation, outer end of
exhaust pipe must have a weather hood with hinged dampers (ob-
tain locally).
NOTE: Weather hood should be installed at least 12 in-
ches [305 mm] above the ground. Larger clearances
may be necessary for installations where heavy snow-
fall can occur.
Number of 90° Elbows
Weather Hood Type
Recommended
Use Only for Short Run Installations
D673I_SVG
1
1
1.
4 in. [102 mm]
D802I_SVG
1
1.
2.5 in. [64 mm]
Maximum length of 4 in. [102 mm] diameter rigid metal duct.
0
65 feet [19.8 m]
55 feet [16.8 m]
1
55 feet [16.8 m]
47 feet [14.3 m]
2
47 feet [14.3 m]
41 feet [12.5 m]
3
36 feet [11.0 m]
30 feet [9.1 m]
4
28 feet [8.5 m]
22 feet [6.7 m]
Table 2
NOTE: Deduct 6 feet [1.8 m] for each additional elbow.
NOTE: The maximum length of a 4 in. [102 mm] diame-
ter flexible metal duct must not exceed 7.87 ft. [2.4 m],
as required to meet UL2158, clause 7.3.2.A.