Log Button
When the Console is connected to the Sprayer Station, pressing
the Log button starts the logging of weather data. The recording
interval is specified in the ConsoleSync program. The interval rang-
es from four seconds to one minute, and can also be disabled. Data
will be recorded at the specified interval until the Log button is
pressed again. The Console will beep to indicate logging has been
initiated or discontinued. “Log” is displayed on the fourth line of the
LCD while the Console is logging data.
Diagnostic Mode
If the Log button is pressed and held while the Console is switched
on, the Console will enter a diagnostic mode. The Console will beep
twice before displaying the diagnostic screens.
For more information on the Console’s diagnostic mode, see
“Troubleshooting” (p. 29).
Snapshot Button
When the Console is connected to the Sprayer Station, pressing
the Snapshot button records the geo-referenced weather data cur-
rently displayed on the LCD. The Console will beep to indicate a
record has been captured. Snapshot data is maintained in files sep-
arate from logged records.