4
Specifications
Hard Case with Handle—8 3/4” x 7” x 4” deep
Relay Specifications:
Internal relay 250 V, 1 Amp AC or DC
Maximum switching power 60 W or 60 VA.
Operating Temperature Range: Limited by the batteries being used.
Most Alkaline batteries have a recommended operating range of -.4°F
to 131°F (-18°C to 55°C)
Uses 4-AA batteries (not included) to power the electronic controls and
display (but not the cell phone)
If a prepay phone is running low on funds, the alert phone call might be
intercepted by the low funds notification.
On prepaid accounts, some carriers send a text message or voice call
after the first call of the day. Be sure to test how your service works.
If your phone supports it, the speed dial option is preferable to the re-
dial option. Redial calls the last number dialed or the last number that
called the phone. This may cause it to dial an incorrect number.
Speed dial will always call the pre-programmed number.
Important cell phone information
Temperature Range
-40° to 140°F (-40° to 60°C)
Accuracy
±1.1ºF (±0.6°C) at -4 to 122°F (-20 to 50°
C), else ±2.2°F (±1.2°C)
Humidity
Range
0% - 100%
Water
Range
0 (dry) to 15 (wet), typical threshold level
for irrigation events is 5.00