Spectron Relion-MR-Exm Operating Manual Download Page 1

 

 

Agreed: 

 

FSUE “VNIIFTRI” 

 

OS VSI “VNIIFTRI”  

 

 
 

EXPLOSION-PROOF 

MONITOR 

“Relion-МR-Exm” 

Operating Manual 

SPEC.732197.000.000-01 RE 

 

 

 

 

 
 
 
 
 
 

2018 

Summary of Contents for Relion-MR-Exm

Page 1: ...Agreed FSUE VNIIFTRI OS VSI VNIIFTRI EXPLOSION PROOF MONITOR Relion МR Exm Operating Manual SPEC 732197 000 000 01 RE 2018 ...

Page 2: ...Screen diagonal 19 Body galvanized steel Heating Relion МR Exm N LCD 14 ver 04 06 Screen diagonal 17 Body stainless steel Heating Relion МR Exm М LCD 14 ver 04 06 Screen diagonal 17 Body galvanized steel Heating The monitor is manufactured in compliance with requirements to ex proof equipment as per TR TS 012 2011 GOST 30852 0 IEC 60079 0 GOST 30852 10 IEC 60079 11 GOST 30852 17 IEC 60079 18 and h...

Page 3: ...R Exm 14 14 Resolution Relion МR Exm 24 1920 x 1080 Relion МR Exm 21 1920 x 1080 Relion МR Exm 14 1366 x 768 Matrix type IPS Matrix lighting LED Screen cover Matt Height to width aspect ratio 16 9 Vertical vision angle 178 Horizontal vision angle 178 Response time ms 7 Update rate Hz 60 Brightness kd m2 250 Contrast ratio 1000 1 Pixel size mkm 247 Pixel density ppi 102 Frequency at maximum resolut...

Page 4: ...steel 12X18H10T or with low carbon steel St10 20 with polymer powder coating Wall mounted swivel arm supplied upon request shall be made with stainless steel 12X18H10T or low carbon steel St10 20 with polymer powder coating Adjustment angles for monitor installed at a swivel arm in horizontal plane shall be 60 degrees in vertical plane 30 degrees Fig 2 Monitor view 1 body 2 screen 3 arm fixturing ...

Page 5: ...erface of the HDMI or VGA monitor is made in an ex proof area For this purpose the monitor is equipped with a transmitter Transmitter is connected with the monitor with a UTP cable twisted pair The cable line is connected to terminals in commutation section from one side and is clamped with connector RJ45 and connected to transmitter from the other side The length of the cable line from the monito...

Page 6: ...een menu and get an ability to change settings press and hold button for 10 seconds Table 2 Screen menu functions Sign in the main menu Submenu Description Elements of control and adjustment Analogue Brightness Contrast Brightness Adjustment of screen brightness Contrast Contrast adjustment i e difference between light and dark areas DCR Activation of dynamic adjustment of contrast OFF ON Game Bri...

Page 7: ... Green Increase and reduction of the green component in the image Blue Increase and reduction of the blue component in the image Save Save user s color density Input video signal This monitor shall receive signal from HDMI Other inputs are inactive Scaling Select image type Original AR ratio of dimensions to input signal Full Screen scans the image to full screen Over Drive Improvement of response...

Page 8: ...y maintenance and repair operations of the monitor shall be performed in compliance with the safety regulations specified for the facility Maintenance personnel shall be responsible for occupational safety When communication cables are installed the following rules must be followed the communication line shall be located at distance from power cables the communication line cable shall cross the po...

Page 9: ...maintenance and emergency operations easy access to the monitor shall be provided 4 2 Monitor assembly Prior to installation perform visual examination of the unit The body cable gland and screen glasses shall not have any damages Make sure the cover sealing of the switching compartment at the back of the monitor is intact Check for availability of all fastening elements bolts nuts washers Cabling...

Page 10: ...he explosion hazard area to an ex proof area connect clamp RJ45 Fig 7 and connect it to the transmitter Connect the cable from the computer recorder to the HDMI transmitter Switch on the monitor and transmitter power Switch on the monitor and perform settings in compliance with i 4 2 of the Manual 4 3 Water resistance Ensure airtightness of the connections and lid of the communication compartment ...

Page 11: ...periods specified by technical guidelines of the organization with regard to production conditions but not less than once a year When performing technical maintenance of the monitor examine the following integrity of the body absence of dents or other mechanic damages integrity of the screen glass availability of all fixing elements and components quality of connections presence of ex proofing mar...

Page 12: ...UFACTURER S WARRANTY Specified lifetime for the monitor is 10 years minimum Warranty period is 12 months since commissioning but not longer than 48 months since sale After 24 months of service supplementary warranty period shall be issued via service WARRANTY EXTENSION at http spectron ops ru Warranty repairs are in compliance with GOST R IEC 60079 19 and the monitor shall be replaced by the manuf...

Page 13: ...PS 1 pc Example of ordering records in documentation 1 Provide full name of the monitor Example Relion МR Exm М LCD 21 ver 05 2 Provide the name of the wall mounted swivel arm bracket not included in supply available upon request Example Relion VPU K M MANUFACTURER S ADDRESS tel 2D Lenin St Beryozovsky Sverdlovsk Oblast 623700 Russia tel 7 343 379 07 95 info spectron ops ru www spectron ops ru ...