background image

IMPORTANT SAFETY INSTRUCTIONS

 

1. Read all instructions.
2. Care must be taken, as burns can occur from touching hot parts.
3. Do not operate the lamp with a damaged cord or if the lamp has been damaged. 
4. 

Do not look directly into the UV light. Wear UV-absorbing protective eyewear (such as 

the UVS-30 glasses provided) when operating this or any UV lamp. Never operate the 
lamp with the UV filter lens removed.

5. Never operate this equipment in any manner not specified in these instructions because the 

protection provided by the equipment may be impaired.

6. Adequate ventilation should be provided when working on operating combustion engines.
7. This unit is not recommended for high-dust environments.

GENERAL INFORMATION  

  

1. Install the UV bulb and the Bulb-Saver™ (packed separately). 
2. Connect the plug to a power outlet that complies with the electrical requirements specified on 

the lamp's label.

3. Turn ON the lamp. Allow approximately 3 to 5 minutes for the lamp to reach full lighting  

intensity. If the lamp fails to light, check that the bulb is completely screwed into the socket.

4. When the lamp is used intermittently and frequently, do not turn it off until the inspection is 

complete. Any interruption in the power supply, such as a drop in voltage or changing power 
outlets, will cause the bulb to go out. The bulb must then cool for a minimum of 5 minutes 
before restarting. Continuous operation will also extend the bulb life.

5. The lamp housing and filter will become hot during continuous operation. Do not touch these 

components. We recommend using the 

optional

 Spectroline HGS-100A heat guard/stand for 

increased protection.

OPERATOR SERVICING 
Do not perform any servicing that is not covered in these instructions. Return the lamp to 
the factory for maintenance not covered in this section.

HOUSING AND FILTER MAINTENANCE

Always unplug the lamp from the power outlet before performing any maintenance or  

• 

servicing. Allow the UV lamp to cool before handling

.

Immediately clean spills from the housing with water and a mild detergent and wipe dry. 

• 

Periodically clean the filter with a glass cleaner and a soft cloth. 

BULB/FILTER INSTALLATION OR REPLACEMENT

 

Use 

only

 a Spectroline

®

 100S/M UV bulb. Using any other bulb may damage the unit and 

will void the warranty.

1. Detach the silicone-rubber filter holder by peeling it from around the circumference of the lamp 

housing. The filter will remain inside the filter holder. (If replacing the filter, press it firmly but 
gently inside the filter holder.) Set the filter holder aside.

2. Place the UV bulb through the Bulb-Saver™/collar in the lamp housing. Turn the bulb 

clockwise

 gently but firmly into the socket with the fingertips. (If removing an existing bulb, turn 

it 

counterclockwise

.)  

Do not operate the lamp without the Bulb-Saver.

3. Reattach the filter holder by pressing it with the heel of your hand around the circumference of 

the lamp housing. Be sure the groove in the filter holder seats over the rim of the housing. 

UV INTENSITY VERIFICATION  

To ensure that your SB-100P is operating at the required UV intensity, it should be checked 
periodically. The AccuMAX

TM

  XRP-3000 radiometer/photometer kit uses a dual-wavelength 

UV-A/VIS sensor detector to accurately measure ultraviolet irradiance or visible light. The 
AccuMAX XR-1000 digital readout unit with the XS-365 UV sensor or the Spectroline DM-365XA 
digital readout unit are also recommended for accurate UV-A measurement. The meters are 
specially designed to measure the UV irradiance from 320–400nm with a peak at 365nm.

For more information about these units, please contact the Customer Service Department at 
Spectronics Corporation. In the U.S. and Canada, call toll-free 1-800-274-8888. Outside the U.S. 
and Canada, call 516-333-4840.

SPECIAL PURPOSE FILTERS

  

The SB-100PC Series lamps are equipped with a 2F100C clear filter that reduces transmission 

• 

of medium wave (UV-B) and short-wave (UV-C) radiation to safe levels, while permitting high 
UV-A energy for curing applications.
The SP-100PY semiconductor wafer inspection lamp is equipped with a 2F475Y yellow filter 

• 

that blocks the emission of wavelengths shorter than 500nm, protecting against activation of 
the photoresist during semiconductor wafer inspection.
The SB-100PD Series lamps are equipped with a 2F350 diffusing filter that produces a  

• 

"diffused spot" beam of UV-A light.

                           

SB-100P Series

Long Wave UV Lamps

English

DANGER

Ultraviolet radiation emitted from this product. Avoid exposure. ALWAYS 
WEAR PROTECTIVE CLOTHING. EXPOSURE MAY CAUSE PREMATURE 
AGING OF THE SKIN AND CANCER. ALWAYS WEAR PROTECTIVE 
EYEWEAR; FAILURE TO DO SO MAY RESULT IN SEVERE BURNS OR LONG 
TERM INJURY TO EYE. Never look directly into the lamp. Exposure can 
cause eye and skin allergy and allergic reactions. Medications or cosmetics 
may increase your sensitivity to ultraviolet radiation. Consult physician 
before operating this product if you are using medications or have a history 
of skin problems or believe yourself especially sensitive to sunlight.

FOR PROFESSIONAL EXAMINATION USE ONLY

(1,1)  -1- SB-100P Series AM06002-8.indd 11/1/2010 4:32:28 PM

(1,1)  -1- SB-100P Series AM06002-8.indd 11/1/2010 4:32:28 PM

Summary of Contents for SB-100P Series

Page 1: ...ly inside the filter holder Set the filter holder aside 2 Place the UV bulb through the Bulb Saver collar in the lamp housing Turn the bulb clockwise gently but firmly into the socket with the fingertips If removing an existing bulb turn it counterclockwise Do not operate the lamp without the Bulb Saver 3 Reattach the filter holder by pressing it with the heel of your hand around the circumference...

Page 2: ... 120V European 230V British 230V Australian 240V or Japanese 100V For additional information contact Spectronics Corporation Série SB 100P Lampes UV à ondes longues DANGER Ce produit émet des rayonnements ultraviolets Éviter toute exposition PORTER TOUJOURS DES VÊTEMENTS DE PROTECTION UNE EXPOSITION PEUT PROVOQUER UN VIEILLISSEMENT PRÉMATURÉ DE LA PEAU ET UN CANCER PORTER TOUJOURS DES LUNETTES DE ...

Page 3: ...é 2 Insérez l ampoule UV à l intérieur du col Bulb Saver du logement de la lampe Faites tourner l ampoule doucement mais fermement dans le sens des aiguilles d une montre en serrant seulement avec les doigts afin de l installer dans la douille Pour retirer une ampoule existante faites la tourner dans le sens contraire des aiguilles d une montre No faites pas marcher la lampe sans le Bulb Saver 3 R...

Page 4: ...30 V en Australie 240 V ou au Japon 100 V Pour plus de renseignements contactez Spectronics Corporation IMPORTANTES INSTRUCCIONES DE SEGURIDAD 1 Lea todas las instrucciones 2 Tenga cuidado pues puede quemarse al tocar partes calientes 3 No opere la lámpara con un cable averiado o si la lámpara ha sufrido algún daño 4 No mire directamente a la luz ultravioleta Use las gafas de protección que absorb...

Page 5: ...anecillas del reloj No opere la lámpara sin antes colocado el Bulb Saver protector de bombilla 3 Para volver a conectar el portafiltros presiónelo con la base de la mano alrededor del círculo en la caja de la lámpara Asegúrese de que la ranura en el portafiltro quede asentada sobre el reborde de la caja VERIFICACIÓN DE INTENSIDAD DE LUZ UV Para asegurar que su lámpara funcione con la intensidad de...

Page 6: ...HTIGE SICHERHEITSHINWEISE 1 Vor dem Gebrauch sind alle Anweisungen durchzulesen 2 Bitte seien Sie bei der Handhabung vorsichtig da es bei Kontakt mit heißen Teilen zu Verbrennungen kommen kann 3 Betreiben Sie die Lampe nicht wenn deren Anschlussschnur oder die Lampe selbst beschädigt ist 4 Schauen Sie keinesfalls direkt in das UV Licht Beim Einsatz dieser oder einer anderen UV Lampe muss eine UV a...

Page 7: ... sollte diese regelmäßig überprüft werden Das AccuMAX XRP 3000 Radiometer Photometer Set ist mit einem Zwei Wellenlängen UV A VI Sensordetektor ausgestattet sowohl die UV Strahlungsintensität als auch das sichtbare Licht akkurat zu messen Das AccuMAX XR 1000 Digitalablesungsgerät mit dem XS 365 UV Sensordetektor oder das Spectroline DM 365XA Digitalablesungsgerät empfehlen sich auch für die akkura...

Page 8: ...2 Bulb Saver 5 EC 0116 Fassung mittleres Unterteil 120V 102931 Fassung mittleres Unterteil 230 240V EC 0116 Fassung mittleres Unterteil 100V 6 124736 Lampengehäuse 7 103767 Platte rückseitige Abdeckung 8 100310 Pistolengriff 9 118677 Handgriff Vorschaltgerät 10 MC 0157 Befestigungsblock 11 MC 0158 Stift 12 SA 0101 Baugruppe Vorschaltgerät 120V 105049 Baugruppe Vorschaltgerät 230 240V 118989 Baugru...