DISASSEMBLING THE FILTER PROTECTOR FOR MAINTENACE
The outer rubber cover/filter holder may be removed periodically to clean the glass filter.
To disassemble the Filter Protector, first remove the front rubber cover/filter holder. Peel the
rubber cover/filter holder toward the front portion of the lamp.
The glass filter will remain inside the protector. To remove the glass filter, peel around the
edge of the rubber cover/filter holder and push the glass filter out. To replace or reinsert
the glass filter into the rubber cover/filter holder, slide the glass filter into the channel of the
rubber cover/filter holder. Manipulate the rubber cover around the filter. Ensure the glass
filter is evenly seated.
REPLACING THE UV LENSES
The UV-A lenses covering the UV-A LEDs must be replaced over time. They will solarize
(become cloudy and yellow) from repeated use. A set of detailed instructions come with the
replacement UV-A lenses. See Replacement Parts section and contact Customer Service
for more details.
ENVIRONMENTAL SPECIFICATIONS
The Vintage™ 365 series lamps are designed to be safe under the following conditions:
• For Indoor Use;
• Temperature 41°F to 122°F (5°C to 50°C);
• Mains supply voltage fluctuations not to exceed ±10% of the nominal voltage.
LIMITED WARRANTY
The warranty policy for the Vintage™ 365 lamp is provided on the Certificate of Limited
Warranty enclosed separately with each unit.
NOTE:
For assistance of any kind, please
contact the Customer Service Department at Spectro-UV. Provide the model, the serial
number of the unit, and the date of purchase.
NOTE:
Be sure to use genuine Vintage™ 365 replacement parts. Using another manufac-
turer’s replacement parts could affect product performance and will void the warranty.
Summary of Contents for Spectroline Vintage 365
Page 6: ...6 ...
Page 12: ...12 ...
Page 18: ...18 ...
Page 24: ...24 www Spectro UV com 4 Dubon Ct Farmingdale NY 11735 866 230 7305 ...