Technical Description
TM888300 Rev. (Al), August 2019
21
detectors) to a host computer or universal controller for central monitoring. This
feature enables easy maintenance, with local and remote diagnostic tools.
3.3.9
Tilt Mount
The newly designed stainless steel tilt mount provides a smaller installation
footprint that can conform to limited space constraints, while the sturdy
construction maintains alignment even with constant vibration. The improved X
and Y axis worm-gear adjustments provide quick and easy alignment for
installation and maintenance procedures.
3.4
Product Certification
There are 4 open path Quasar 950/960 certifications.
3.4.1
ATEX, IECEx
The Quasar 950/960 is approved per ATEX and IECEx certifications:
•
ATEX Ex II 2(2)G D
Ex db eb ib [ib Gb] IIB+H2 T4 Gb
Ex tb IIIC T135°C Db
•
T Ambient
–
55°C to +65°C
This product is suitable for use in hazardous zones 1 and 2 with IIB+H2 group
vapors present, and zones 21 and 22 with IIIC combustible dust types.
3.4.2
SIL-2
The Quasar 950/960 is TUV approved for SIL-2 requirements per IEC 61508.
According to SIL-2 requirements, the alert condition can be implemented by an
alert signal via the 0
–
20mA current loop.
3.4.3
TR CU/EAC
The Open Path Quasar 950/960 is in compliance with the standard TR CU
012/2011 per:
1Ex db eb ib
[
ib Gb
]
IIB+H2 T4 Gb X
Ex tb IIIC T135
°
C Db X
–
55
°
C
≤
Ta
≤
+
65
°
C
For more details, see TR CU certificate No. Т
R CU C-
US.МЮ62.В.
05536.
3.4.4
Inmetro (UL)
The Quasar 950/960 is in compliance with the standards ABNT NBR IEC 60079-0,
ABNT NBR IEC 60079-1, ABNT NBR IEC 60079-7, ABNT NBR IEC 60079-11, ABNT
NBR IEC 60079-31, and INMETRO decree No. 179 as of May 18th, 2010. Further
details may be found on Certificate of Compliance No. UL-BR 16.106XX.