SafEye
™
™
Series 200 IR Gas Detector - User’s and Maintenance Manual
SPETCREX INC.
Doc. No. TM792100, Rev. B, Oct..1997
- 20 -
1. 11. 4.
Environmental Specifications
The SafEye system is designed to withstand harsh environmental conditions. The
source and detector units compensate for adverse conditions while maintaining
accuracy.
a.
High Temperature:
Designed to meet MIL-STD-810C, method 501.1 procedure II
Operating temperature:
+55 degrees C (+131 degrees. F)
Storage temperature:
+65 degrees C (+149 degrees. F)
b.
Low Temperature:
Designed to meet MIL-STD-810C, method 502.1, procedure I
Operating temperature:
-20 degrees C (-4 degrees. F)
Storage temperature:
-40 degrees C (-40 degrees F)
c.
Humidity:
Designed to meet MIL-STD-810C, method 507.1, procedure IV
Relative humidity of up to 95% for the operational temperature range.
d.
Salt and Fog:
Design to meet MIL-STD-810C, method 509.1 procedure I.
Exposure to a 5% salt solution for 48 hours.
e.
Water and Dust:
IP67 per En60529
IP66 per En60529
Dust:
Totally protected against dust.
Liquids:
Protected against immersion between 15 cm and 1m in depth. Protected
against all water jets from all directions.
f.
Shock and Vibration:
Vibration:
Designed to meet MIL-STD-810C, method 514.2, procedure VIII.
Mechanical Shock: Designed to meet MIL-STD-810C, method 516.1, procedure I.
g.
Electromagnetic Compatibility (EMC):
The detector is design and approved according to the following EMC requirements:
Electrostatic Discharge (ESD)
IEC1000-4-2:1995-1.
Conducted emission:
EN55011, Class B.
Radiated emission:
EN55011, Class B.
Radiated immunity:
ENV50140:1994 (80-1000 MHz).
EFT/B:
IEC801-4: 1988.