Fig. A: Single-Membrane Filter Diagram

Encapsulated 

 TFC RO Membrane

(MEM-90-ENC)

1 micron 

Carbon Block 

Filter (CF-1-10)

1 micron MicroTec™

Sediment Pre-Filter

(SF-MT-1-10)

System Information

Fig. B: Dual-Membrane Filter Diagram

2 Encapsulated 

TFC RO Membranes

(MEM-90-ENC)

1 micron 

Carbon Block 

Filter (CF-1-10)
1 micron MicroTec™

Sediment Pre-Filter

(SF-MT-1-10)

Silica-Buster

DI Cartridge

(DI-SB-CI-10)

Silica-Buster

DI Cartridge

(DI-SB-CI-10)

SpectraPure

®

SpectraPure®Inc

 Fax  480.894.6109 Fax us toll-free 1.877.527.7873

E-mail: [email protected] Visit us on the web www.spectrapure.com

21

System Troubleshooting Guide

Product Water -  Low Production Rate

Cause 

  Corrective 

Action

Plugged pre-filters 

Replace pre-filters

Low water temperature 

Heat feed water or use higher GPD membrane

Low feed pressure 

Use booster pump or use higher GPD membrane

Fouled membrane 

Replace membrane 

Membrane Troubleshooting Guide

The following chart illustrates the procedure for determination of RO membrane 
performance. However, the chart represents only rough guidelines for determin-
ing performance of RO membrane. Depending on your tap water chemistry, the 
rejection characteristics of the membrane may vary significantly. 

Method of  Calculate %   

 

 

Test Results  

Conclusion

 Testing  

Rejection

TDS/ 

 

Measure feed water and  Is Rejection   

No - Replace Membrane

Conductivity   RO product water TDS/ 

greater than   

Yes - Membrane OK

Tester  Conductivity 

   95% 

?

Alkalinity  

Measure feed water and  Is Rejection   

No - Replace Membrane

Test Kit   

RO product water  

 

greater than   

Yes - Membrane OK

   Alkalinity    90% 

?

Hardness 

*Measure feed water   

Is Rejection   

No - Replace Membrane

Test Kit   

and RO product water  

greater than   

Yes - Membrane OK

   Hardness    90%?

*Caution: This test is not to be used on softened water sources.

Membrane Testing

Summary of Contents for The Eliminator DI

Page 1: ...f membrane elements for one year from date of receipt by the buyer providing that the loss of performance was not caused by fouling neglect or water conditions exceeding the feed water parameters list...

Page 2: ...ane 19 20 Membrane Testing System Troubleshooting Guide 21 Membrane Troubleshooting Guide 21 System Care Tips for Long Membrane Life 22 Storage 22 Choosing a Mounting Location 22 System Components Rep...

Page 3: ...Temperature Extremes 1 The unit must be kept out of areas that are subject to freezing temperatures 2 High temperatures greater than 100 F 38 C must be avoided If the unit is used outside avoid puttin...

Page 4: ...Low water temperature Heat feed water or use higher GPD membrane Low feed pressure Use booster pump or use higher GPD membrane Fouled membrane Replace membrane Membrane Troubleshooting Guide The follo...

Page 5: ...3 X Y 143 ppm 4 X Y X 143 150 0 953 5 Rejection X Y X 100 0 953 100 95 3 Membrane Hardness Rejection 95 3 Membrane OK Production Rate SpectraPure SpectraPure Inc Fax 480 894 6109 Fax us toll free 1 87...

Page 6: ...illiliters per Minute 5 If the actual concentrate flow rate is less than the optimum concentrate flow rate you must reduce the length of the flow restrictor capillary tubing as described on the next p...

Page 7: ...ncentrate tubing Fig C for Single Membrane System or Fig D for Dual Membrane System Remove the tubing from its push fitting at the membrane as follows a Firmly depress and hold the push fitting collar...

Page 8: ...ail and remove the blue product water inter connect tubing 9 Lift the dual RO membrane assembly from the holding clips 10 Separate the two membranes by depressing the collar on the push fitting of the...

Page 9: ...mbrane 1 Membrane 2 feed push fitting black inter connect feed tubing blue product water interconnect tubing Membrane 1 concentrate push fitting Membrane 1 product water push fitting SpectraPure Spect...

Page 10: ...raPure SpectraPure Inc Fax 480 894 6109 Fax us toll free 1 877 527 7873 E mail spectra spectrapure com Visit us on the web www spectrapure com 15 Note The flow restrictor assembly should remain uninst...

Page 11: ...as described in the Removal Adjustment and Replacement section on page 7 Snap the membrane assembly back into its holding clips System Maintenance RO Membrane Replacement If you have a Single Membran...

Page 12: ...and check for leaks System Maintenance SpectraPure SpectraPure Inc Fax 480 894 6109 Fax us toll free 1 877 527 7873 E mail spectra spectrapure com Visit us on the web www spectrapure com 13 System Mai...

Reviews: