SANITIZING THE SYSTEM:
(It is recommended that you sanitize the system once a year.)
1. Turn tap water source off and remove all filters from the system,
including the RO membrane.
2. Mix together hot water, soap and a little bleach.
3. Scrub filter housings and rinse with clean tap water to remove soap and
bleach.
4. Place filters back into housings and reconnect lines.
SYSTEM STORAGE:
1. It is recommended that you store your RO System in a cool and dark
place when not being used.
2. Your RO System must always be protected from freezing or
temperatures above 113° F (45° C).
7. Place the black housing O-ring on the housing rim and carefully screw
the lid back on to the base. Hand-tighten.
8. Reconnect the black tubing to the membrane feed push fitting.
9. If you have a dual-membrane system (-180), perform steps 2 thru 8 on
the second membrane.
10. Open the Flush Valve and allow the system to flush for several minutes
to remove any loose particles.
11. Close the Flush Valve and turn on the water supply to the system.
12. Check for leaks.
RO MEMBRANE REPLACEMENT: (continued)