SpectraPure
®
SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
10
SYSTEM INSTALLATION & INITIALIZATION:
1. Attach the black tap water tubing to the left side of the Sediment Filter Housing
(See page 8).
2. Attach the yellow drain line to the “Y”- connector at the rear of the system. This “Y”
-connector already has a yellow and red tube attached to it. (See page 9)
3. Attach the blue product line to the rear port of the
right-hand DI housing (Left-side housing when
viewed from rear. See image on right).
4. Attach the black tubing and elbow(s) to the
membrane housing cap(s). (See page 9)
5. Attach the garden hose adapter
(connected to
the black tubing)
to your cold water source.
6. Remove the two DI filter cartridges from the two right-hand filter housings.
Reconnect the two housings to their threaded caps. Hand tighten.
7. The provided ball valve can be located at a convenient place on the black tap
water line. Cut the black tubing in two and reconnect the two cut ends with
the ball valve. This will allow you to cut off the water supply to service the RO/
DI system without affecting the household water supply.
8. Place the
yellow concentrate (waste) tubing
and the
blue purified (product)
water tubing
temporarily into a drain. Do not restrict flow from these lines.
9. Let both tubings run water down the drain for 20 minutes.
10. Reinstall the two DI cartridges into the DI housings. Hand tighten.
(continued on next page)
•
Most of the components of this system are plastic and are subject to damage
by ultraviolet light from the sun and other sources such as metal halide
lighting.
•
Avoid installing this unit in an area where it may be subjected to bright
light or direct sunlight, as algae is more likely to thrive inside the clear filter
housings when exposed to bright light. The unit must be kept out of
areas that are subject to freezing temperatures.
•
High temperatures greater than 113° F (45° C) must be avoided. If the unit
is used outside, avoid putting the system in direct sunlight or connecting
it to a garden hose that may be exposed to sunlight.
CAUTION