Effective on products purchased after March 10, 2005. 

SpectraPure, Inc.® warrants the product to the original owner only to be free of defects in material and 
workmanship for a period of three years from the date of receipt. SpectraPure’s liability under this warranty 
shall be limited to repairing or replacing at SpectraPure’s option, without charge, F.O.B. SpectraPure’s factory, 
any product of SpectraPure’s manufacture. SpectraPure will not be liable for any cost of removal, installation, 
transportation or any other charges which may arise in connection with a warranty claim. Products which are 
sold but not manufactured by SpectraPure are subject to the warranty provided by the manufacturer of said 
products and not by SpectraPure’s warranty. SpectraPure will not be liable for damage or wear to products 
caused by abnormal operating conditions, accident, abuse, misuse, unauthorized alteration or repair or, if the 
product was not installed in accordance with SpectraPure’s or other manufacture’s printed installation and 
operating conditions, or damage caused by hot water, freezing, flood, fire or acts of God. 

SpectraPure will not be responsible for any consequential damages arising from installation or use of the 
product, including any water or mold damage due to flooding which may occur due to malfunction or faulty 
installation, including, but not limited to failure by installer to over- or under-tighten fittings, housings, and/
or push-style fittings, or improper installation of push-style fittings. Consumable items such as pre filters and 
membranes are not covered under the two year warranty.

SpectraPure warrants (pro-rated) the performance of tested SpectraSelect™ RO membrane elements only, for 
one year from date of receipt by the buyer, providing that the loss of performance was not caused by  fouling , 
neglect or water conditions exceeding the feed water parameters listed in the applicable product manual (refer 
to detailed membrane warranty information). SpectraPure will, on confirmation of loss of performance during 
the warranty period, credit the pro-rated amount of the current catalog price of the element. The disposable 
filters and  cartridges are not covered under the warranty.

To obtain service under this warranty, the defective system or components must be returned to SpectraPure 
with proof of purchase, installation date, failure date and supporting installation data. Any defective product 
to be returned to the factory must be sent freight prepaid; documentation supporting the warranty claim and 
a Return Goods Authorization (RGA) number must be included. SpectraPure will not be liable for shipping 
damages due to the improper packaging of the returned equipment and all returned goods must also have 
adequate insurance coverage and a tracking number. 

SpectraPure will not pay for loss or damage caused directly or indirectly by the presence, growth, proliferation, 
spread or any activity of “fungus”, wet or dry rot or bacteria. Such loss or damage is excluded regardless of 
any other cause or event that contributes concurrently or in any sequence to the loss. We will not pay for loss 
or damage caused by or resulting from continuous or repeated seepage or leakage of water, or the presence 
or condensation of humidity, moisture or vapor, that occurs over a period of 14 days or more. “Fungus” and 
“fungi” mean any type or form of fungus or Mycota or any by-product or type of infestation produced by 
such fungus or Mycota, including but not limited to, mold, mildew, mycotoxins, spores, scents or any biogenic 
aerosols. 

SpectraPure will not be liable for any incidental or consequential damages, losses or expenses arising from 
installation, use, or any other causes. There are no expressed or implied warranties, including merchantability 
or fitness for a particular purpose, which extend beyond those warranties described or referred to above.

* The three year limited warranty does not apply to consumable items, including but not limited to, 

filters and cartridges unless specifically stated above

THREE YEAR MANUFACTURERS WARRANTY

Summary of Contents for MC-RODI-UHE-400

Page 1: ...C RODI UHE 400 INSTRUCTIONS WARNING Please read carefully before proceeding with installation Failure to follow any attached instructions or operating parameter may lead to the product s failure and possible damage to property REV 02 17 2010 ...

Page 2: ...cement 12 Reverse Osmosis Diagnostics 12 Reverse Osmosis Membrane Performance Testing 13 Reverse Osmosis Membrane replacement 14 Tips for long membrane life 14 De Ionization Cartridge maintenance and replacement 15 Troubleshooting Guide 16 Warranty Information 17 Replacement Parts List 18 Copyright 2009 by SpectraPure Inc ALL RIGHTS RESERVED No part of this publication may be reproduced stored in ...

Page 3: ...GPD 1 20 0 2 Micron Zeta Zorb Sediment Filter 1 20 0 5 Micron Carbon Block 1 20 MaxCap DI Cartridge 1 20 Silica Buster DI Cartridge 1 High Flow Re Circ Pump 1 UHE Module 1 Pressure Regulator CONTENTS OF UHE WATER SYSTEM IF ANY OF THE ITEMS LISTED ABOVE ARE MISSING PLEASE CONTACT SPECTRAPURE PRIOR TO INSTALLATION ALL RETURNS WITHOUT RMA WILL BE REFUSED CLAIMS MUST BE WITHIN 10 DAYS FROM RECEIPT 1 L...

Page 4: ...our SilicaBuster cartridge These two cartridges remove the remaining silicates phosphates and nitrates left by an RO membrane High and Low Float Operation 1 Floats are to be mounted horizontal when dry and float up when wet NOTE Pressure switches could also be used with pressure tanks Please call for more details 2 When the bottom float goes dry the input solenoid INSOL is opened and one second la...

Page 5: ...ld at least 10 gallons ELEVATION FOR SYSTEM When mounting your UHE make sure it is elevated above your fresh water reservoir 2 TOOLS RECOMMENDED FOR INSTALLATION 3 INTRODUCTION TO PUSH FITTINGS Push fittings are similar to a Chinese finger trap toy In order to release its grip from tubing Firmly depress and hold the push fitting collar down with your thumbnail While the push fitting collar is depr...

Page 6: ... for the first time or replacing either DI cartridges it is very important that you rinse the MaxCap DI cartridge with the downstream DI removed There is a large ionic load present in a new MaxCap DI cartridge Failure to flush this cartridge will shorten the life of the down stream DI TOP VIEW NOTE When mounting your UHE make sure it is elevated above your fresh water reservoir ...

Page 7: ...h Float shuts down the system while the Low Float turns the system on B Connect the floats to the Y adapter C Attach the 3 pin connector on the float switches to the HI REC MODULE NOTE Floats are to be mounted horizontal when dry and float up when wet In most instances we recommend locating the low float approx half way down your reservoir DO NOT OVERTIGHTEN when installing the floats STEP 4 For n...

Page 8: ...h 1 4 blue and 3 8 yellow lines side by side and observe the flow rates b Slowly adjust the waste flow adjustment valve W F Adj shown on page 6 until the flows appear to be equal NOTE The waste flow can be slightly less than the product c Get two measuring cups and a stop watch to measure the waste and product water Make sure you have equal measurements and adjust accordingly Note NEVER close the ...

Page 9: ...n and it will not affect the operation of the DI system STEP 11 CONNECT BULKHEAD FITTINGS Bulkhead Fitting MUST be installed on the same container that the floats are on SEE DIAGRAM ON PAGE 7 METER 1 IN Tap Water OUT RO Water 3 8 BULK HEAD FITTING Use a paddle bit and carefully drill a 13 16 hole for installation at the bottom of the reservoir below the low level float 1 4 BULK HEAD FITTING Use a ...

Page 10: ...t all fittings are tight and leak free before leaving the system unattended The concentrate line yellow includes a smaller capillary tube flow restrictor that is located inside of the tubing Do not remove or discard this restrictor the system will not produce permeate water without the flow restrictor Downstream of the flow restrictor is a Waste Flow Adjustment Valve W F Adj shown on page 6 used t...

Page 11: ...th clean hot water 5 Install the new pre filter into the housing Screw the housing back onto the assembly and hand tighten only NOTE Do not use filter wrench to tighten housings Over tightening will damage housings and void your warranty 6 Proceed with carbon block filter replacement METERING AND DIAGNOSTICS The digital TDS meter left side will provide a reliable means of evaluating the efficiency...

Page 12: ...al between the input and output numbers In order to accurately determine the condition of the RO Membrane a conductivity tester TDS meter capable of reading the tap water conductivity and the permeate water conductivity has been provided with this system With the assistance of the first meter 1 Dual TDS meter you will be able to easily determine the RO membrane s condition Before performing the di...

Page 13: ...RESSURE CORRECTION DOW FilmTec s Standard for Total Dissolved Solids in the water is 250 Your first step is to subtract what your water is from DOW s standard Next Step subtract your current house pressure with the osmotic pressure This is your corrected tap water pressure PRESSURE COMPENSATION Now take you corrected pressure and divide it by the standard PSI set by the industry Which is 60 PSI Mu...

Page 14: ...ttom of the membrane housing When the membrane is aligned with the hole firmly push the membrane into the hole until it bottoms out 8 Place the black housing O ring on the housing rim and carefully screw the lid back on to the base 9 Reconnect the black tubing to the membrane feed push fitting TIPS FOR LONG MEMBRANE LIFE 1 Replacement of 0 2 micron sediment filter at least once every 6 months This...

Page 15: ... DI cartridge 3 Make sure the DI cartridge is installed in the correct direction as marked on the cartridge shell and be sure that the top seal is securely attached to the top of the cartridge 4 Tighten the cartridge housing by rotating it clockwise and hand tighten 5 Turn on system and check for leaks REPLACEMENT PROCEDURE FOR DI CARTRIDGES Materials Needed Filter wrench and DI cartridges Procedu...

Page 16: ... horizontal not drooping 3 Extremely high production rate a Ruptured membrane i Replace membrane 4 Milky colored water a Air in system i Air in the system is a normal occurrence with initial start up of the RO DI system This milky appearance will disappear during normal use within 1 2 weeks If condition reoccurs after filter changes drain tank 1 to 2 times 5 The water in the Pure Water container d...

Page 17: ...ater parameters listed in the applicable product manual refer to detailed membrane warranty information SpectraPure will on confirmation of loss of performance during the warranty period credit the pro rated amount of the current catalog price of the element The disposable filters and cartridges are not covered under the warranty To obtain service under this warranty the defective system or compon...

Page 18: ...3 MEM 300 RO Membrane Replacement Membrane 3rd Stage 4 DI MC 20 MaxCap DI MaxCap De ionizaiton Cartridge 4th Stage 5 DI SB 20 Silica Buster DI Silica Buster De ionizaiton Cartridge 5th Stage 6 FR 25 90 Flow Restrictor 90 gallon a day Flow Restrictor 7 VA CK IL 1LB 4GJ Check Valve 1 LB Check Valve 8 PUMP ROT IM 140 SS High Flow Re Circ Pump Re Circluation Pump Replacement Parts Optional Accessories...