TIPS FOR LONG MEMBRANE LIFE:
1. Replacement of 5 micron carbon block filter at least once every
6 months or when chlorine breakthrough occurs or when water
production is severly reduced. This will ensure good membrane life
and protect the membrane from chlorine damage.
2. Membrane should not be operated at lower than the specified 2:1
concentrate to purified water ratio.
3. Operating reverse osmosis systems on softened feed water greatly
reduces the chances of membrane fouling.
4. Use an optional flush valve
after each use
of the system to extend
membrane life.
STORAGE
1. It is recommended that you store your RO System in a cool place when
not being used.
2. Your RO System must always be protected from freezing or
temperatures above 113° F (45°C).
TROUBLESHOOTING GUIDE:
Product Water - Low Production Rate
Cause
Corrective Action
Plugged prefilters
Replace prefilters
Low water temperature
Heat feed water or use higher GPD membrane
Low feed pressure
Use booster pump or use higher GPD membrane
Fouled membrane
Replace membrane