INSTALLING BALL VALVE ON TANK
STEP 1. If there is not Teflon tape applied to the nipple on the tank, wrap (7-12 turns)
around the pipe threads (MPT) on the Stainless Steel fitting.
STEP 2. Thread the Ball Valve (supplied in the parts bag) onto the stainless steel nipple
on top of the tank. Hand-tighten only.
NOTE: The storage tank is pressurized with air at the factory to 6 psi with the tank
totally drained. Over a period of time, air may leak out causing the delivery rate
of the stored water to decrease. If this occurs, verify correct tank pressure using
a low pressure air gauge on the tire valve stem located on the bottom, or near
the flange at the top of the tank with tank completely empty of water.
TANK INSTALLATION
1. Position tank in desired location. Stand it upright (using the black plastic stand). Measure the distance from the Quick
Connect fitting on the rear “Y” on the LEFT side of the unit (when viewed from the front) over to the tank and cut a
piece of 3/8" Blue tube to length.
2. Connect that 3/8" Blue tube to the LEFT side “Y” and to the Right-Angle Ball Valve that is attached to the top of the
tank.
3. Measure and cut another length of 3/8" Blue tube and connect it to the quick connect tubing adapter on the
Threaded Shaft of the faucet and to the Quick Connect fitting on the rear “Y” on the RIGHT side of the unit (when
viewed from the front).
4. Connect the 3/8" Black tube to the hose barb on the faucet and to the Drain Saddle. Tighten the compression nut.
3/8" Blue Tubing
out to Tank
3/8" Blue Tubing
out to Faucet
REAR VIEW
Connections Out to Faucet and Tank