MOUNTING SYSTEMS INSTALLATION
STEP 1. Determine best location for the RO system to be mounted to allow for future system maintenance. Use
two (2) self tapping screws and a Phillips screwdriver. Measure the distance between the key hole slots on the
back of the bracket and install screws .
Leave enough space and tubing so that you
can pull the system out for maintenance.
1. Slowly turn the cold water supply to full flow. Check for leaks. Turn off the ball valve at the storage tank and
open the faucet.
- Watch the clear housings fill with water. When water comes out of the faucet, turn the faucet off.
The system will pressurize rapidly and should shut off with a “click”.
NOTE:
It is important that air is purged from system during initial operation. To do this, orient the RO unit with the
product (permeate) and reject (brine) water ports pointing upwards. (Round end of RO membrane housing is up,
pre-filter housings are horizontal). Allow a minimum of 15 minutes operation with this orientation.
2.
Look for leaks and do not leave the system alone until you are sure there are no leaks.
Now, turn the valve on
the tank to the “ON” position.
3. Before using the system, allow three tank fillings to occur, then flushing the contents between each filling by locking
the faucet lever to the open position until drained.
4. Wait for an hour before drawing water from of the faucet.
Note: NEVER RUN HOT WATER (>100°F) THROUGH THE SYSTEM.
START-UP PROCEDURES