15
08
3.3 Settings
It is used to set the prescription. In NMES mode, press
,
the selected pre-
scription will blink, press
or
to select the desired prescription, press
again to confirm the selection.
3.3.1 Setting/Enter Button
3.3.2 Selection Buttons
In NMES mode, press
or
to select prescription, there are 5 default
prescriptions for selection. For the 5 default prescriptions, the first 4 are fixed,
and 5th can either be downloaded from the APP or manually set through the
stimulator.
3.3.3 Play/Pause button
In ETS or NMES mode, Press
to start training, press again to pause.
Note: is only used in “ETS” or “NMES” mode.
3.3.4 Intensity Adjustment Buttons
In
ETS
o
r
N
MES
m
ode
,
t
he
i
nitial
c
urrent
i
s
0
m
A
,
p
ress
t
o
i
ncrease
t
he
i
ntensity
,
p
ress
to
d
ecrease
t
he
i
ntensity
.
At 0-5 mA, the current will increase in 1mA increments;
At 5-21 mA, the current will increase in 0.5mA increments;
At 21 mA and more, the current will increase in 0.1mA increments.
3.3.5 Mode Button
When the stimulator is turned on, it automatically defaults to ETS mode,
press
, to switch among ETS, NMES and GAME.
3.3.6 Power Button
Press
and hold on for 2 seconds to turn on the stimulator
,
press again to
turn off the stimulator. When the stimulator is in charging, press once to show
battery level.
3.3.7 Stimulation output/EMG input port
It
is
f
or
e
lectrical
s
timulation
o
utput
a
nd
E
MG
i
nput
c
ollection
.
Chapter 5 Care and Maintenance
Stimulator
* Wipe the surface once a week with a slightly water dampened cloth or antiseptic wipe.
* Do not use cleaning sprays or alcohol based cleaning solutions.
* Do not store in direct sunlight, in high temperatures, moist areas, dusty areas or
near corrosive gas.
* Do not immerse in water.
* Do not throw, step on or exert pressure on the stimulator.
* When the stimulator reaches the end of its service life (3 years), please dispose
of it in accordance with the local and national regulations.
Battery
The Aspire2 is a rechargeable stimulator with a universal recharging USB cable.
The cable can be used to recharge your stimulator through a computer USB port
or the provided power adapter.
Any attempt to replace the batteries or charge the stimulator
differently than
instructed in this manual may result in overheating of the battery and or fire.
To recharge the stimulator:
1) Open the connection port cover located on the bottom of the stimulator,
2) Connect the recharging cable to the stimulator,
3) Plug the other end into the USB port on your computer or place the adapter
onto the end of the cable and plug into a 110 Volt wall outlet,
4) When finished close the connection port cover,
5) The stimulator is now ready to use again.
The
stimulator
is
designed
to
work
for
Ten
(
10
)
hours
with
a
full
charge
.
The
stimulator
will
need
to
charge
for
about
Three
(
3
)
hours
when
completely
drained
of
power
.
Note: Do not use the device while charging
.
Battery
specification
Type
:
Polymer
Lithium
-
Ion
Battery
Model
:
E423150
Capacity: 650 mAh
Voltage: 7.4V
Power Adapter
Type: Medical Power Supply
Model: GTM41078-0605-USB
Input: 100-240V, 50-60Hz, 0.3A
Output: 5V 1.2A
The power adapter conforms to the standards of IEC 60601-1.
* NOTE
:
you
must
first
press
the
"
"
in
NMES & ETS
mode
before
pressing
the
"
"
to
increase
intensity
.