background image

Spectracom 

 

NetClock 

NetClock 9483 Option Card Installation Guide, Rev.2

   

6

 

IMPORTANT NOTE:

 If installing the PTP option card, additional steps may be desired, depending upon 

the NetClock’s Reference Priority Input configuration – refer to the following section. 
 

Reference Priority Input Configuration 

IMPORTANT  NOTE:

  Adding or removing option module cards impacts the Reference Priority Input 

configuration of the NetClock in the following manner: 

When adding or removing option module cards with configured  Input References, any user-defined 
Reference Priority Input setup configuration will be reset.  It is recommended to avoid this by taking the 
following steps: 

1.  Save your current NetClock configuration. 
2.  Power down NetClock unit and install option card (outlined below).  
3.  Power up NetClock unit. 
4.  Restore the previously backed up NetClock configuration. 

If these steps are

  not

  taken, the NetClock’s Reference Priority table will be reset back to the factory 

default state for the NetClock hardware configuration, and the user / operator will need to reconfigure the 
Reference Priority Table.  For additional information on managing the Reference Priority Table, refer to 
the 

NetClock 9400 Series Instruction Manual

 

Safely power down NetClock unit and remove chassis cover. 

CAUTION

: 

NEVER install an option card from the back of the unit, ALWAYS from the top. 
It is therefore necessary to remove the top cover of the main chassis (housing).

 

 

 

If standoffs are not already installed, screw standoffs into the corners of  the module  populating 
bottom 

Slot 3

 

Insert the PTP  option card into 

Slot 4

  (lining up the card  screw holes with the standoffs), and 

using screwdriver, screw the option card into the standoffs. 

 

Connect any required cables and secure option card into place. 

 

Replace chassis cover, power on the unit. 

 

Login to the NetClock web interface; verify the installed option card is identified by the NetClock. 

 

If you had backed up your NetClock configuration, optionally restore the previously saved 
configuration (as previously noted). 

 

Summary of Contents for NetClock 9483

Page 1: ...NetClock 9483 Time and Frequency Synchronization System Option Card Installation Guide 1209 5000 0052 Rev 2 November 2016...

Page 2: ...on Card Installation Instructions 3 Section B Specific Option Card Installation Instructions 5 Multi Gigabit Ethernet Option Card Installation 5 T1 E1 120 Ohm Option Card Installation 5 PTP Option Car...

Page 3: ...mmunications equipment Display clocks Security building access systems fire alarm systems The NetClock 9483 also includes backwards compatibility support with all previous generation NetClock products...

Page 4: ...of option card installation please carefully read the following safety statements and precautions to ensure that the NetClock unit has been safely and properly powered down with all AC and DC power co...

Page 5: ...re designated as Slot 1 Slot 6 as shown Figure 1 NetClock 9483 rear panel option module bay slots General Option Card Installation Instructions IMPORTANT NOTE Each of the available option cards must b...

Page 6: ...nel or if existing option card already installed in top Slot 2 or 4 use screwdriver to unscrew and remove the card from standoffs If standoffs are not already installed screw standoffs into the corner...

Page 7: ...iver screw the option card into the standoffs Connect any required cables and secure option card into place Replace chassis cover power on the unit Log in to NetClock web interface verify the installe...

Page 8: ...ority table will be reset back to the factory default state for the NetClock hardware configuration and the user operator will need to reconfigure the Reference Priority Table For additional informati...

Page 9: ...a web browser and log in to the NetClock web interface Navigate to the STATUS INPUTS and or STATUS OUTPUTS pages Information displayed on these pages will vary depending upon your option module card...

Page 10: ...d properly proceed with the Software update as described below to ensure NetClock and the newly installed card are using the same latest available version Updating the System Software Even if the newl...

Page 11: ...North American or European service centers or visit the Spectracom website at www spectracom com NOTE Premium Support Customers can refer to their service contracts for emergency 24 hour support North...