HAX and VAX Lubrication Instructions

Lubricate the Thomson Rod

April 2012

HAX and VAX Lubrication Instructions—Spectra T950 Library

10

5.

Using the supplied applicator, apply a thin, even layer of HAX grease 
(green or blue, PN 90948180) to the reachable portions of the Thomson 
rod. Use enough grease so that the shaft has a slippery film over its 
entire surface, with no excess grease.

Note:

You can use any non-shedding, non-scratching applicator to 
apply the grease.

6.

Slowly and gently pull the VAX column to the end of the Thomson rod; 
then push the VAX column back along the Thomson rod, as far as you 
can reach. 

As you move the VAX column, listen for any abnormal sounds (for 
example, metal-on-metal grinding or screeching). Contact Spectra 
Logic Technical Support if any abnormal sounds are detected (see 

Spectra Logic Technical Support on page 2

).

7.

Repeat Step 5 and Step 6 until the linear bearing block’s interior grease 
reservoirs are filled with grease. The bearings will then be able to 
distribute the grease evenly along the entire length of the Thomson rod. 

You will be able to tell that the linear bearing block’s grease reservoirs 
are sufficiently filled when a uniform ring of excess grease gathers at 
the end of the Thomson rod. 

8.

Wipe away any excess grease with a lint-free cleaning wipe.

Note:

Do not use alcohol.

Figure 12

Apply a thin, even layer of HAX grease over 

the Thomson rod’s reachable surface.

Figure 13

Even distribution of grease over the 

Thomson rod’s entire surface.

Foam 

Thomson rod

Applicator

Thomson rod

Uniform ring of

excess grease

Summary of Contents for T950

Page 1: ...SpectraLogic com Spectra T950 Library HAX and VAX Lubrication Instructions...

Page 2: ...r its use Due to continuing research and development Spectra Logic may revise this publication from time to time without notice and reserves the right to change any product specification at any time w...

Page 3: ...0949168 white in color Ensure ESD Protection The repair environment for the library must be free of conditions that could cause electrostatic discharge ESD To protect the library from ESD follow these...

Page 4: ...described in your library s User Guide 3 Pause PostScan if it is running as described in your library User Guide Any tapes currently being scanned are returned to their storage locations Take the VAX...

Page 5: ...position on the right hand side of the library Remove the Right Side Access Window Panel Use the following steps to remove the right side access panel from the library 1 Use a 1 8 inch Allen wrench o...

Page 6: ...middle of the VAX column 2 Use a large binder clip to pinch the two sides of the VAX belt together securing the elevated transporter in place Note The VAX belt is the long belt located on the left si...

Page 7: ...grease Do not apply an excessive amount of grease Any excess grease will be pushed to the top and bottom end of the VAX linear rail 4 Use the supplied foam applicator to apply a thin layer of grease t...

Page 8: ...VAX linear rail bearings will spread the grease along the rail Note As you move the transporter listen for any abnormal sounds for example metal on metal grinding or screeching Contact Spectra Logic...

Page 9: ...he VAX column as viewed from the front of the transporter 3 Gently push the bottom of the VAX column to move it toward the center of the library so that you can access as much of the Thomson rod as po...

Page 10: ...ample metal on metal grinding or screeching Contact Spectra Logic Technical Support if any abnormal sounds are detected see Spectra Logic Technical Support on page 2 7 Repeat Step 5 and Step 6 until t...

Page 11: ...f the panel on the hooks on the sides of the opening in the end of the frame 2 While holding the panel steady with one hand slide the panel down into place 3 Use a 1 8 inch Allen wrench or hex screwdr...

Reviews: