Spectra GmbH & Co. KG
User Manual
[email protected] Spectra PowerBox 310 77
5.2 DIO Hardware Specification
XCOM+/ 2XCOM+: Isolated power in V+
XCOM-/ 2XCOM-: Isolated power in V-
Isolated power in DC voltage: 9~30V
8x / 16x Digital Input (Source Type)
Input Signal Voltage Level
‐
Signal Logic 0: XCOM+ = 9V,
Signal Low
-
V-
< 1V
XCOM+ > 9V,
V+
-
Signal Low
> 8V
‐
Signal Logic 1: >
XCOM+
-
3V
Input Driving Sink Current:
‐
Minimal: 1 mA
‐
Normal: 5 mA
8x / 16x Digital Output (Open Drain)
‐
DO Signal have to pull up resistor to XCOM+ for external device, the
resistance will affect the pull up current
‐
Signal High Level: Pull up resistor to XCOM+
‐
Signal Low Level: = XCOM-
‐
Sink Current: 1A (Max)