Spectra GmbH & Co. KG
User Manual
[email protected] Spectra PowerBox 310 17
Physical Design
• Fanless Design
• Cableless Design
• Jumper-less Design
• Unibody Design
Reliability & Protection
Reverse Power Input Protection
• Yes
Over Voltage Protection
• Protection Range: 51~58V
• Protection Type: shut down operating voltage, re-power on at the present level to
recover
Over Current Protection
• 15A
Surge Protection
• 3.84 kV (impedance 12 ohm 1.2/50us waveform)
CMOS Battery Backup
• SuperCap Integrated for CMOS Battery Maintenance-free Operation
MTBF
• MTBF:
513,628 hours
- Database: Telcordia SR-332 Issue3, Method 1, Case 3
Operating System
Windows
• Windows® 10
Linux
• Supports by project
Environment
Operating Temperature
• -40°C to 70°C
* PassMark BurnInTest: 100% CPU, 2D/3D Graphics (without thermal throttling)
* With extended temperature peripherals; Ambient with air flow
• * According to IEC60068-2-1, IEC60068-2-2, IEC60068-2-14
Storage Temperature
• -40°C to 85°C
Relative Humidity
• 95%RH @ 70°C (non-Condensing)
EMC
• CE, FCC, ICES-003 Class A, EN50121-3-2 (Railway), E-mark
Safety
• IEC/EN 62368-1
* Product Specifications and features are for reference only and are subject to change without prior
notice. For more information, please refer to the latest product datasheet from our website.
Summary of Contents for PowerBox 310 Series
Page 1: ...Spectra PowerBox 310 Series USER MANUAL Version 1 00 December 2021 ...
Page 13: ...Spectra GmbH Co KG User Manual sales spectra de Spectra PowerBox 310 13 ...
Page 44: ...Spectra GmbH Co KG User Manual sales spectra de Spectra PowerBox 310 44 ...
Page 47: ...Spectra GmbH Co KG User Manual sales spectra de Spectra PowerBox 310 47 Chapter 4 BIOS Setup ...
Page 70: ...Spectra GmbH Co KG User Manual sales spectra de Spectra PowerBox 310 70 ...
Page 71: ...Spectra GmbH Co KG User Manual sales spectra de Spectra PowerBox 310 71 ...