  6

 

 

VOICE COMMANDS

VOICE COMMANDS

VOICE COMMANDS

VOICE COMMANDS::::

 

 

##TVxx 

VOICE TIMEOUT AFTER THE VEHICLE IS STOPPED OR, IN VOX MODE, TIMEOUT AFTER THE 
LAST NOISE IN THE ROOM 
xx = 01->98 MINUTES 
xx = 05 DEFAULT 

 
##Vx 

 

MICROPHONE SENSIVITY 
X = 1 -> 3 
x = 1 MINIMUN 
x = 2 MEDIUM 
x = 3 MAXIMUM (DEFAULT) 

 

##MOVx 

ENABLE THE SHOCK SENSOR AND SET THE MOTION SENSIVITY 
x = 0->9 
x = 0 HIGH SENSIVITY, A LITTLE MOVMENT IS ENOUGH TO TRIGGER THE UNIT (DEFAULT) 
x = 9 LOW SENSIVITY, A LONG AND DURABLE MOVMENT IS NECESSARY TO TRIGGER THE 

 

 

UNIT. 

WARNING:

WARNING:

WARNING:

WARNING:    WHEN THIS COMMAND WILL BE DECODED, THE UNIT WILL DO AN HARDWARE 

RESET AND WILL RESTART WITH THE NEW CONFIGURATION. 

THIS CONFIGURATION WILL AUTOMATICALLY DISABLE THE ##VOXxx OPTION

THIS CONFIGURATION WILL AUTOMATICALLY DISABLE THE ##VOXxx OPTION

THIS CONFIGURATION WILL AUTOMATICALLY DISABLE THE ##VOXxx OPTION

THIS CONFIGURATION WILL AUTOMATICALLY DISABLE THE ##VOXxx OPTION.... 

 

##VOXxx 

ENABLE THE VOX SENSOR AND SET THE VOX LEVEL. 
xx = 01->99 
xx = 00 HIGH SENSIVITY VOX, IS ENOUGHT A LITTLE NOISE TO TIGGER THE UNIT 
xx = 99 LOW SENSIVITY VOX, AN HIGH AND DURABLE NOISE IS NECESSARY TO TRIGGER  

 

 

THE UNIT 
(IS A GOOD WAY DON’T SET THIS VALUE BELOW 10 TO AVOID FAKE TRIGGER 
CAUSED FROM ELECTRICAL NOISE) 

WARNING

WARNING

WARNING

WARNING::::    WHEN THIS COMMAND WILL BE DECODED, THE UNIT WILL DO AN HARDWARE 

RESET AND WILL RESTART WITH THE NEW CONFIGURATION. 

THIS CONFIGURATION WILL AUTOMATICALLY DISABLE THE ##MOVx OPTION.

THIS CONFIGURATION WILL AUTOMATICALLY DISABLE THE ##MOVx OPTION.

THIS CONFIGURATION WILL AUTOMATICALLY DISABLE THE ##MOVx OPTION.

THIS CONFIGURATION WILL AUTOMATICALLY DISABLE THE ##MOVx OPTION.    
WHEN BABI IS CONFIGURED IN VOXxx MODE, YOU CAN NOT CALL AND LISTEN IT WITH A 

PHONE, ONLY THE BABI THAT CAN CALL YOUR PHONE AT THE PROGRAMMED NUMBER. 

 

##EFxxx   

ENABLE DSP PARAMETER WHEN THE CAR IS MOVING 
xxx = 004 ENABLE NOISE SUPPRESSION FUNCTION 
xxx = 255 DISABLE THE DSP FUNCTIONALITY (DEFAULT) 

 

##RV 

 

IMMEDIATELY START ONE VOICE RECALL ON THE PRE PROGRAMMED VOICE NUMBER. 

 

##RAV   

ENABLE THE VOICE RECALL ON MOTION / VOX EVENT 
THIS FUNCTION MUST BE ENABLED FOR USE THE MOV/VOX TRIGGER OPTION 

 

##RAI 

 

ENABLE THE INFINITY VOICE RECALL, ALWAYS WITHOUT MOTION/VOX (24h/24h) 

 

    

Summary of Contents for FW V1.3

Page 1: ...a email it spektra email it spektra email it spektra email it 1 USER USER USER USER MANUAL MANUAL MANUAL MANUAL FOR FOR FOR FOR GSM GSM GSM GSM QUAD QUAD QUAD QUAD BAND AUDIO TRANSMITTER BAND AUDIO TR...

Page 2: ...UST all the command MUST all the command MUST all the command MUST be sent with uppercase be sent with uppercase be sent with uppercase be sent with uppercase c c c charact haract haract haracter er e...

Page 3: ...____________________________ _________________________________ __________________________________ _ _ _ pag 6 pag 6 pag 6 pag 6 REMOTE DEBUG MESSAGES REMOTE DEBUG MESSAGES REMOTE DEBUG MESSAGES REMOTE...

Page 4: ...BER INCOMING NUMBER IF SET THE UNIT WILL ACCEPT ONLY CALL FROM THE PROGRAMMED NUMBER NVxxx SET THE VOICE OUTGOING NUMBER VOICE OUTGOING NUMBER VOICE OUTGOING NUMBER VOICE OUTGOING NUMBER THE UNIT WILL...

Page 5: ...LISTED IN THE FOLLOWING TABLE x 1 15 MINUTES x 2 30 MINUTES x 3 60 MINUTES x 4 90 MINUTES x 5 2 HOURS x 6 4 HOURS x 7 8 HOURS x 8 16 HOURS x 9 20 HOURS WHEN THE MESSAGE IS DECODED THE UNIT WILL SHUTDO...

Page 6: ...IS CONFIGURATION WILL AUTOMATICALLY DISABLE THE VOXxx OPTION VOXxx ENABLE THE VOX SENSOR AND SET THE VOX LEVEL xx 01 99 xx 00 HIGH SENSIVITY VOX IS ENOUGHT A LITTLE NOISE TO TIGGER THE UNIT xx 99 LOW...

Page 7: ...RIBED AT THE PAG 4 OF THIS MANUAL KIND OF UNIT NAME VERSION FW D1 NMov NON PROG NStop NON PROG NVoce NON PROG NEntr NON PROG D2 REQUEST THE STATUS OF THE INFORMATION DESCRIBED AT THE PAG 5 6 OF THIS M...

Page 8: ...I IS PROGRAMMED IN VOX MODE VOXxx IS ENABLE MOVx DISABLE AT THE POWER ON YOU WILL SEE 10 LED FLASHES WARNING WARNING WARNING WARNING WHEN BABI IS CONFIGURED IN VOXxx MODE YOU CAN NOT CALL AND LISTEN I...

Page 9: ...http spektra dyndns org http spektra dyndns org spektra email it spektra email it spektra email it spektra email it 9 DIFFERENT MODE DIFFERENT MODE DIFFERENT MODE DIFFERENT MODE OF POWER SUPPLY OF POW...

Page 10: ...ON Noise reduction function SECTION TRANSMITTER SECTION TRANSMITTER SECTION TRANSMITTER SECTION TRANSMITTER POWER SUPPLY Two different solutions 7 26 Vdc internally stabilized trough an high efficient...

Reviews: