background image

SpectraPure

SpectraPure®Inc.

  

480.894.5437   Call us toll-free  1.800.685.2783    

2167 East Fifth St,    Tempe, Arizona   85281

®

12

6.  Re-insert the yellow tubing into its push-fitting in the RO membrane as
 follows:
 

a.)  Moisten the O-ring seal inside the concentrate outlet fitting by dripping

 

 

a few drops of clean water into the fitting. 

 

b.)  Grasp the yellow tubing near the flow restrictor end, and insert the

 

 

tubing into the push-fitting. Push the tubing into the fitting until 

 

 

resistance is felt, approximately 1/2 inch (12.7 mm). The tubing is now 

 

 

resting on the O-ring seal inside the fitting.

 

c.)  Firmly push the tubing approximately an additional 1/4 inch

 

  

(6.35 mm) further into the fitting to completely seat the line into 

 

 

the fitting and O-ring seal.

7.  Turn on the system water supply and check for leaks prior to further  use or  
 

testing. If a leak is observed, you may not have pushed the yellow tubing  

 

into the push-fitting far enough to seal the tubing against the O-ring. Turn  

 

off the system water supply and reseat the tubing as described above.

yellow tubing

capillary tubing 

plastic insert

Fig. D:  Flow Restrictor Assembly 

Fig. C: Reverse Osmosis Assembly

Top/Rear View

membrane 

feed 

push-fitting

black 

tubing to 

membrane 

feed

RO membrane

yellow concentrate tubing

blue purified water 

tubing

black feed water 

tubing

(Waste Water)

(Good Water)

(Tap Water)

SpectraPure®Inc

 Fax  480.894.6109 Fax us toll-free 1.877.527.7873

E-mail: [email protected] Visit us on the web www.spectrapure.com

13

SpectraPure

®

SEDIMENT PRE-FILTER REPLACEMENT

For maximum contaminant removal and long membrane life, the sediment  
pre-filter must be changed when a 15-20% drop in pressure is observed OR at 
least 6-month intervals. If your water contains a great deal of sediment the 
pre-filter may require more frequent changes to maintain adequate production 
rate and extended membrane life. 
Sediment Pre-Filter Replacement

Materials Required: 

 0.5-micron MicroTec™  Sediment Filter (SF-MT-0.5-10), 

Filter Wrench

Procedure: 

(FIRST FILTER ON LEFT)

 

1.  Turn off water supply to the system.

 

2.  Refer to photo on page 6. Using the provided filter wrench, remove  

 

 

 

the first housing on the left. Unscrew it counterclockwise as viewed   

 

  from 

the 

bottom.

 

3.  Remove the old filter and discard.

 

4.  Thoroughly wash the housing with a mixture of hot soapy water and a    

 

 

few teaspoons of household bleach. Rinse well with clean hot water.

 

5.  Install the new pre-filter into the housing, 

Screw the housing back onto the

 

 

 assembly, and hand tighten 

only

 

 

NOTE: Do not use filter wrench to tighten housings. Over-tightening will 

 

 

damage housings and void your warranty.

 

6.  Proceed with carbon block filter replacement.

CARBON BLOCK FILTER REPLACEMENT

For maximum contaminant removal and long membrane life, the carbon 
pre-filter must be changed at least ever 6-month or when chlorine breakthrough 
greater than 0.1 ppm occurs in the yellow concentrate line. Test for chlorine 
breakthrough by collecting a 10 ml sample of the concentrate from the yellow 
tubing and test the chlorine concentration using test kit TK-CL-10. If the chlorine 
concentration is above 0.1ppm, replace the carbon pre-filter.

Materials Required: 

 0.5 micron Carbon Block Filter (CF-0.5-10),  Filter Wrench, 

Chlorine Test Kit (TK-CL-10)

Procedure: 

(SECOND FILTER ON LEFT WHEN FACING SYSTEM)

1.  Perform steps 1-5 listed above
2.  Turn on system water supply and check for leaks.

Summary of Contents for THE MAXCAP RO/DI System

Page 1: ...ilter Wrench Optional Accessories Model Optional Part FAU SMP Quick Connect Faucet Coupler TK CL 10 Total Chlorine Test Kit VA FVK 4 Flush Valve Kit BPLF MO 115 Low Flow Booster Pump 115V BPLF MO 230...

Page 2: ...for any consequential damages arising from installation or use of the product including any water or mold damage due to flooding which may occur due to malfunction or faulty installation including bu...

Page 3: ...ered purchaser After repair or replacement the factory will return the unit or part freight prepaid to the customer 2 We assume no warranty liability in connection with our equipment other than as her...

Page 4: ...sure greater than 80 psi will require a pressure reducing valve SpectraPure Inc Fax 480 894 6109 Fax us toll free 1 877 527 7873 E mail spectra spectrapure com Visit us on the web www spectrapure com...

Page 5: ...water is passed through a 0 5 micron Micro Tec sediment pre filter This filter is required to remove excess turbidity particulate matter that may cause the carbon block filter to plug 2 The second st...

Page 6: ...ure When the prefilters are new the pressure shown on the gauge will be slightly less than the actual tap water pressure and as the filters age the pressure will drop due to the dirt that will collect...

Page 7: ...vi Acidify feed water to the RO membrane to improve its rejection h Faulty monitor probe Test and Replace if required SpectraPure Inc Fax 480 894 6109 Fax us toll free 1 877 527 7873 E mail spectra s...

Page 8: ...at is located inside of the tubing Do not remove or discard this restrictor the system will not produce permeate water without the flow restrictor All of the following conditions must be met before wa...

Page 9: ...assure you of maximum life and reliability of your SpectraPure System Failure to perform this procedure can permanently damage the membrane and will void the pro rated Membrane Warranty In order to m...

Page 10: ...RO membrane may be calculated and the resultant number may then be used to determine the condition of the membrane and thus the operator will know when the membrane needs to be replaced Membrane failu...

Page 11: ...te the yellow concentrate tubing Fig C Remove the tubing from its push fitting at the membrane as follows a Firmly depress and hold the push fitting collar down with your thumbnail b While the push fi...

Page 12: ...fe the sediment pre filter must be changed when a 15 20 drop in pressure is observed OR at least 6 month intervals If your water contains a great deal of sediment the pre filter may require more frequ...