Spectra Precision Focus 8 Series Total Station User Guide
3 1
Preparation
2
Setting the measurement mode and preparing the target
The Focus 8 series has two measurement modes: Prism mode (
) and
Reflectorless mode (
). These modes can be changed at any time by holding
down the
or
key for one second.
To set the measurement mode depending on the target you want to measure, see the
following table.
In some cases, you can measure another target that is not appropriate to the set
measurement mode.
Note –
The Focus 8 2" is Laser Class 3R in the Reflectorless mode and Laser pointer
function, and Laser Class 1 in the Prism mode.
Don
’
t sight the Prism when the Laser Pointer is on.
Note –
Focus 8 5"
is a Laser Class 1 in the Prism and Reflectorless mode, and Laser Class 2
in Laser pointer function.
Measurement with a prism
Do not use a prism with scratches, a dirty surface, or a chipped center. Prisms with thin
edges are recommended.
As the Focus 8 series is extremely sensitive, multiple reflections on the prism surface
can sometimes cause a significant loss in accuracy.
Target
Target setting
Prism, reflector sheet
Prism (Prism mode)
Other (reflective materials)
N-Prism (Reflectorless mode)
thin edges
chipped center
thick edges
Summary of Contents for Focus 8 Series
Page 1: ...SPECTRA PRECISION FOCUS 8 SERIES TOTAL STATION...
Page 2: ......
Page 3: ...Version 1 3 0 Revision A Part Number C244E 1 2 February 2010...
Page 10: ......
Page 11: ......
Page 12: ......
Page 20: ...1 Introduction 18 Spectra Precision Focus 8 Series Total Station User Guide...
Page 38: ...2 Preparation 36 Spectra Precision Focus 8 Series Total Station User Guide...
Page 54: ...4 Checking and Adjustment 52 Spectra Precision Focus 8 Series Total Station User Guide...
Page 64: ...5 Specifications 62 Spectra Precision Focus 8 Series Total Station User Guide...
Page 68: ...6 System Diagrams 66 Spectra Precision Focus 8 Series Total Station User Guide...
Page 69: ......