1
Introduction
1 6
Spectra Precision Focus 8 Series Total Station User Guide
Maintenance
Before using the instrument, read and follow the following maintenance instructions:
•
Do not leave the instrument in direct sunlight or in a closed vehicle for
prolonged periods. Overheating the instrument may reduce its efficiency.
•
If the Focus 8 series instrument has been used in wet conditions, immediately
wipe off any moisture and dry the instrument completely before returning the
instrument to the carrying case. The instrument contains sensitive electronic
assemblies which have been well protected against dust and moisture. However,
if dust or moisture gets into the instrument, severe damage could result.
•
Sudden changes in temperature may cloud the lenses and drastically reduce the
measurable distance, or cause an electrical system failure. If there has been a
sudden change in temperature, leave the instrument in a closed carrying case in
a warm location until the temperature of the instrument returns to room
temperature.
•
Do not store the Focus 8 series instrument in hot or humid locations. In
particular, you must store the battery pack in a dry location at a temperature of
less than 30 °C (86 °F). High temperature or excessive humidity can cause mold
to grow on the lenses. It can also cause the electronic assemblies to deteriorate,
and so lead to instrument failure.
•
Store the battery pack with the battery discharged.
•
When storing the instrument in areas subject to extremely low temperatures,
leave the carrying case open.
•
When adjusting the leveling screws, stay as close as possible to the center of
each screw’s range. The center is indicated by a line on the screw.
•
If the tribrach will not be used for an extended period, lock down the tribrach
clamp knob and tighten its safety screw.
•
Do not use organic solvents (such as ether or paint thinner) to clean the
non-metallic parts of the instrument (such as the keyboard) or the painted or
printed surfaces. Doing so could result in discoloration of the surface, or in
peeling of printed characters. Clean these parts only with a soft cloth or a tissue,
lightly moistened with water or a mild detergent.
•
To clean the optical lenses, lightly wipe them with a soft cloth or a lens tissue
that is moistened with alcohol.
Summary of Contents for Focus 8 Series
Page 1: ...SPECTRA PRECISION FOCUS 8 SERIES TOTAL STATION...
Page 2: ......
Page 3: ...Version 1 3 0 Revision A Part Number C244E 1 2 February 2010...
Page 10: ......
Page 11: ......
Page 12: ......
Page 20: ...1 Introduction 18 Spectra Precision Focus 8 Series Total Station User Guide...
Page 38: ...2 Preparation 36 Spectra Precision Focus 8 Series Total Station User Guide...
Page 54: ...4 Checking and Adjustment 52 Spectra Precision Focus 8 Series Total Station User Guide...
Page 64: ...5 Specifications 62 Spectra Precision Focus 8 Series Total Station User Guide...
Page 68: ...6 System Diagrams 66 Spectra Precision Focus 8 Series Total Station User Guide...
Page 69: ......