Screen
Actions and Comments
Fig. 4-21 Instrument Status Menu - Suspend
Instrument Status
Waiting (suspend)
Radio channel: 3
Network ID:
After Starting: If the instrument is inactive for
longer than 5 minutes it will go into Suspend
Mode, see also
and
. The display will
show
Waiting (suspend)
.
The instrument will leave the Suspend Mode by
starting the field software at the instrument, a
short
P
key press or a
z
key press (single
beep).
!
- Indicates Suspend Mode
4 Setup
44 Spectra Precision FOCUS 30 User Guide
Note –
In Suspend Mode - menu shows
Waiting (suspend)
- instrument and telescope
can be turned by hand, whereas StepDrive motor system and Focus system are not
usable
Levelling
Screen
Actions and Comments
Fig. 4-22 Levelling menu
1000
-527
1317
Auto
Once you have selected Level menu, the
electronic bubble appears in Face2 display.
Note –
Values always in 0.1 mgon;
(0.3 mgon = 1”; 0.1 mgon = 1 cc)
Symbols
Telescope direction
Trunnion Axis direction
Bubble Scale value (Auto - max. 35 000; min. 500
)
Instrument inclination > 100mgon
Instrument inclination < 100mgon
Second key functions
N
Scale expansion (Manual mode - min. 100
)
O
Scale reduction (Manual
)
P
Back to Instrument Status menu
Note –
If there is field software at Control
Unit Face1 started, this field software
controls the Face2 display. While using the
field software in every menu the Main
Menu from the Face2 display can be
opened with a long
P
key press!
Fig. 4-23 Levelling menu bubble good adjusted
500
66
-72
Auto
Summary of Contents for Focus 30
Page 1: ...Spectra preciSion 30 TOTAL STATION USER GUIDE...
Page 2: ......
Page 11: ...Spectra Precision FOCUS 30 User Guide IX Declaration of Conformity...
Page 12: ...Declaration of Conformity X Spectra Precision FOCUS 30 User Guide...
Page 16: ...Table of Contents Spectra Precision FOCUS 30 User Guide P N 77701035 Version 1 02...
Page 26: ...2 Inspection Care and Maintenance 10 Spectra Precision FOCUS 30 User Guide...
Page 84: ...4 Setup 68 Spectra Precision FOCUS 30 User Guide...
Page 88: ...5 Instrument Operation Methods 72 Spectra Precision FOCUS 30 User Guide...
Page 125: ......